A Detailed Protocol for Physiological Parameters Acquisition and Analysis in Neurosurgical Critical Patients
Published on: October 17, 2017
Classification of blood pressure in critically ill patients using photoplethysmography and machine learning
Elisa Mejía-Mejía1, James M May1, Mohamed Elgendi2
1Research Centre for Biomedical Engineering, City, University of London, London, United Kingdom.
Objective:
The aim of this study was to evaluate the capability of features extracted from photoplethysmography (PPG) based Pulse Rate Variability (PRV) to classify hypertensive, normotensive and hypotensive events, and to estimate mean arterial, systolic and diastolic blood pressure in critically ill patients.
Methods:
Time-domain, frequency-domain and non-linear indices from PRV were extracted from 5-min and 1-min segments obtained from PPG signals. These features were filtered using machine learning algorithms in order to obtain the optimal combination for the classification of hypertensive, hypotensive and normotensive events, and for the estimation of blood pressure.
Results:
5-min segments allowed for an improved performance in both classification and estimation tasks. Classification of blood pressure states showed around 70% accuracy and around 75% specificity. The sensitivity, precision and F1 scores were around 50%. In estimating mean arterial, systolic, and diastolic blood pressure, mean absolute errors as low as 2.55 ± 0.78 mmHg, 4.74 ± 2.33 mmHg, and 1.78 ± 0.14 mmHg were obtained, respectively. Bland-Altman analysis and Wilcoxon rank sum tests showed good agreement between real and estimated values, especially for mean and diastolic arterial blood pressures.
Conclusion:
PRV-based features could be used for the classification of blood pressure states and the estimation of blood pressure values, although including additional features from the PPG waveform could improve the results.
Significance:
PRV contains information related to blood pressure, which may aid in the continuous, noninvasive, non-intrusive estimation of blood pressure and detection of hypertensive and hypotensive events in critically ill subjects.
More Related Videos
07:51Standardized Hemorrhagic Shock Induction Guided by Cerebral Oximetry and Extended Hemodynamic Monitoring in Pigs
Published on: May 21, 2019
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pre-Procedural Guidelines for Assessing Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: