Clinical Impact of High-Sensitivity Cardiac Troponin T Implementation in the Community
Olatunde Ola1, Ashok Akula1, Laura De Michieli2
1Division of Hospital Internal Medicine, Mayo Clinic Health System, La Crosse, Wisconsin, USA; Center for Clinical and Translational Science, Mayo Clinic Graduate School of Biomedical Sciences, Rochester, Minnesota, USA.
Background:
Limited U.S. data exist regarding high-sensitivity cardiac troponin (cTn) implementation.
Objectives:
This study sought to evaluate the impact of high-sensitivity cardiac troponin T (cTnT) implementation.
Methods:
Observational U.S. cohort study of emergency department (ED) patients undergoing measurement of cTnT during the transition from 4th (pre-implementation March 12, 2018, to September 11, 2018) to 5th generation (Gen) cTnT (post-implementation September 12, 2018, to March 11, 2019). Diagnoses were adjudicated following the Fourth Universal Definition of Myocardial Infarction (MI). Resources evaluated included length of stay, hospitalizations, and cardiac testing.
Results:
In this study, 3,536 unique patients were evaluated, including 2,069 and 2,491 ED encounters pre- and post-implementation. Compared with 4th Gen cTnT, encounters with ≥1 cTnT >99th percentile increased using 5th Gen cTnT (15% vs. 47%; p < 0.0001). Acute MI (3.3% vs. 8.1%; p < 0.0001) and myocardial injury (11% vs. 38%; p < 0.0001) increased. Although type 1 MIs increased (1.7% vs. 2.9%; p = 0.0097), the overall MI increase was largely due to more type 2 MIs (1.6% vs. 5.2%; p < 0.0001). Women were less likely than men to have MI using 4th Gen cTnT (2.3% vs. 4.4%; p = 0.008) but not 5th Gen cTnT (7.7% vs. 8.5%; p = 0.46). Overall length of stay and stress testing were reduced, and angiography was increased (all p < 0.05). Among those without cTnT increases, there were more ED discharges and a reduction in length of stay, echocardiography, and stress tests (all p < 0.05).
Conclusions:
High-sensitivity cTnT implementation resulted in a marked increase in myocardial injury and MI, particularly in women and patients with type 2 MI. Despite this, except for angiography, overall resource use did not increase. Among those without cTnT increases, there were more ED discharges and fewer cardiac tests.
More Related Videos
09:23Using Extraordinary Optical Transmission to Quantify Cardiac Biomarkers in Human Serum
Published on: December 13, 2017
10:12A Sensitive and Specific Quantitation Method for Determination of Serum Cardiac Myosin Binding Protein-C by Electrochemiluminescence Immunoassay
Published on: August 8, 2013
Related Concept Videos
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Acute Coronary Syndrome III: Diagnostic Studies
Acute Coronary Syndrome I: Introduction
Blood Studies for Cardiovascular System II: CRP, Hcy, and Cardiac Natriuretic Peptide Markers
These markers indicate stress or strain on the heart muscle:
Natriuretic Peptides (BNP)
Cardiac myocytes produce these hormones in response to ventricular stretching...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Myocarditis II: Clinical Features and Diagnostic Tests