The OMERACT Knee Inflammation MRI Scoring System: Validation of quantitative methodologies and tri-compartmental
Walter P Maksymowych1, Andrew McReynolds2, Susanne J Pedersen3
1Department of Medicine, University of Alberta, 13-103 Clinical Sciences Building, 11350-83 Avenue, Edmonton T6G 2G3, Alberta, Canada; CARE Arthritis, CARE Arthritis Ltd. 316 Windermere Road NW Unit 210, Edmonton T6W 2Z8, Alberta, Canada.
Objective:
To validate a revised version of the KIMRISS method for quantification of BML and synovitis-effusion in the knee by comparison with an established method, MOAKS.
Methods:
Novel calibration tools were developed for both methods. We compared reliability for status and change scores of BML and synovitis-effusion on baseline and one-year MRI scans.
Results:
Significant increase in both BML and synovitis-effusion was evident using KIMRISS but only for synovitis-effusion using MOAKS. Pre-specified targets for acceptable reliability (≥0.80 and ≥0.70 for status and change scores, respectively) were achieved more frequently for KIMRISS for both BML and synovitis.
Conclusion:
Per OFISA criteria, KIMRISS should progress to assessment of discrimination.