Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo
Published on: October 2, 2021
An adaptive-coherence light source for hyperspectral, topographic, and flow-contrast imaging
Taylor L Bobrow1, Nicholas J Durr1
1Department of Biomedical Engineering, Johns Hopkins University, 3400 N. Charles St., Baltimore, MD 21218. USA.
Abstract:
Colorectal cancer accounts for an estimated 8% of cancer deaths in the United States with a five-year survival rate of 55-75%. The early detection and removal of precancerous lesions is critical for reducing mortality, but subtle neoplastic growths, such as non-polypoid lesions, often go undetected during routine colonoscopy. Current approaches to flat or depressed lesion detection are ineffective due to the poor contrast of subtle features in white light endoscopy. Towards improving colorectal lesion contrast, we present an endoscopic light source with custom laser channels for multimodal color, topographic, and speckle contrast flow imaging. Three red-green-blue laser units, paired with laser speckle reducers, are coupled into endoscopic fiber optic light guides in a benchtop endoscope. Tissue phantom topography is reconstructed using alternating illumination of the laser units and a photometric stereo endoscopy algorithm. The contrast of flow regions is enhanced in an optical flow phantom using laser speckle contrast imaging. Further, the system retains the ability to offer white light and narrow band illumination modes with improved power efficiency, a reduced size, and longer lifetimes compared to conventional endoscopic arc lamp sources. This novel endoscopic light source design shows promise for increasing the detection of subtle lesions in routine colonoscopy screening.
Related Concept Videos
Light Acquisition
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Confocal Fluorescence Microscopy