Related Experiment Video
Updated: Nov 1, 2025

A High-throughput Method for Measurement of Glomerular Filtration Rate in Conscious Mice
Published on: May 10, 2013
Comparison of Plasma Clearance With Early-Compartment Correction Equations and Urinary Clearance in High GFR Ranges
Pierre Delanaye1,2, Emmanuelle Vidal-Petiot3, Thomas Stehlé4
1Department of Nephrology-Dialysis-Transplantation, University of Liège (ULiège), Liège, Belgium.
Introduction:
Glomerular filtration rate (GFR) is measured from the late plasma disappearance curve of an exogenous tracer, after correction for the early decay-corresponding to the distribution of the tracer-using various equations. These equations display the highest discrepancies in the GFR range above 90 ml/min per 1.73 m2, and their respective performances against a reference, urinary GFR measurement are unclear.
Methods:
In patients with mGFR >90 ml/min per 1.73 m2 from 6 different cohorts, we compared GFR obtained from the plasma clearance of iohexol or 51Cr-ethylenediamine tetraacetic acid (EDTA), after correction using Chantler (C), Bröchner-Mortensen (BM), Fleming (F), Jodal-Bröchner-Mortensen (JBM), and Ng (N) equations, with urinary clearance of the same tracers or inulin.
Results:
In 438 participants (median age 41 [39-42] years, 43% women), the median urinary clearance was 100.8 (94.7-112.6) ml/min per 1.73 m2. Plasma clearances using the correction equations were 105.7 (96.8-119.2), 102.4 (95.2-112.9), 100.7 (93.6-111.1), 102.6 (95.2-113.4), and 106.0 (98.2-117.6) ml/min per 1.73 m2 for C, BM, F, JBM, and N, respectively. Concordance correlation coefficients between plasma and urinary clearances were poor for all equations. Compared with urinary clearances, BM, F, and JBM displayed the best accuracy within 10% (73%, 72%, and 71%, respectively, vs. 63% and 66% for C and N), whereas BM and JBM had the lowest median biases. Accuracy of all equations was especially low in the hyperfiltration range (urinary clearance >130 ml/min per 1.73 m2).
Conclusion:
The BM and JBM equations displayed the best overall performances to correct for the early disappearance curve. Results of these equations should be interpreted with caution, especially in the highest GFR range.
Related Concept Videos
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Renal Drug Clearance: Overview
Renal clearance can be calculated using different methods. One approach is to divide the urinary drug excretion rate by the plasma drug concentration. This method directly measures renal clearance, indicating the kidneys' efficiency in...
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
One-Compartment Open Model: Urinary Excretion Data and Determination of k
Clearance Models: Compartment Models

