Related Concept Videos

Reconstruction of Signal using Interpolation01:10

Reconstruction of Signal using Interpolation

431
Signal processing techniques are essential for accurately converting continuous signals to digital formats and vice versa. When a continuous signal is sampled with a period T, the resulting sampled signal exhibits replicas of the original spectrum in the frequency domain, spaced at intervals equal to the sampling frequency. To handle this sampled signal, a zero-order hold method can be applied, which creates a piecewise constant signal by retaining each sample's value until the next...
431
Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

7.5K
The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
7.5K
Aliasing01:18

Aliasing

311
Accurate signal sampling and reconstruction are crucial in various signal-processing applications. A time-domain signal's spectrum can be revealed using its Fourier transform. When this signal is sampled at a specific frequency, it results in multiple scaled replicas of the original spectrum in the frequency domain. The spacing of these replicas is determined by the sampling frequency.
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...
311
Detection of Gross Error: The Q Test01:00

Detection of Gross Error: The Q Test

6.6K
When one or more data points appear far from the rest of the data, there is a need to determine whether they are outliers and whether they should be eliminated from the data set to ensure an accurate representation of the measured value. In many cases, outliers arise from gross errors (or human errors) and do not accurately reflect the underlying phenomenon. In some cases, however, these apparent outliers reflect true phenomenological differences. In these cases, we can use statistical methods...
6.6K
Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving01:29

Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving

147
Mechanistic models play a crucial role in algorithms for numerical problem-solving, particularly in nonlinear mixed effects modeling (NMEM). These models aim to minimize specific objective functions by evaluating various parameter estimates, leading to the development of systematic algorithms. In some cases, linearization techniques approximate the model using linear equations.
In individual population analyses, different algorithms are employed, such as Cauchy's method, which uses a...
147
Residuals and Least-Squares Property01:11

Residuals and Least-Squares Property

8.2K
The vertical distance between the actual value of y and the estimated value of y. In other words, it measures the vertical distance between the actual data point and the predicted point on the line
If the observed data point lies above the line, the residual is positive, and the line underestimates the actual data value for y. If the observed data point lies below the line, the residual is negative, and the line overestimates the actual data value for y.
The process of fitting the best-fit...
8.2K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Beyond Algorithms: Conceptual Innovation in Medical Imaging AI.

ArXiv·2026
Same author

Dual-Carbon Synergistic Strategy Enabling SbPO<sub>4</sub>@MFC/rGO Composites With Hierarchical Conduction Network for High-Performance Sodium-Ion Batteries.

Small (Weinheim an der Bergstrasse, Germany)·2026
Same author

Application of learned ideal observers for estimating task-based performance bounds for computed imaging systems.

Journal of medical imaging (Bellingham, Wash.)·2026
Same author

Asiaticoside alleviates inflammation and intestinal barrier dysfunction in Crohn's disease-like colitis in a manner associated with the RhoA/ROCK/MLC pathway.

Naunyn-Schmiedeberg's archives of pharmacology·2026
Same author

Observation of QED Effects, Breit Interaction, and Electron Correlation in Highly Charged Au Ions Produced by a High-Power Laser.

Physical review letters·2026
Same author

Observer-usable Information as a Task-specific Image Quality Metric.

IEEE transactions on medical imaging·2026
Same journal

Correction to "On the shape of the radiation survival curve in tumor spheroids: The role of oxygen heterogeneity".

Medical physics·2026
Same journal

Multi-view constrained semi-supervised vertebra detection for 3D ultrasound spine volume.

Medical physics·2026
Same journal

Accuracy of quantitative <sup>177</sup>Lu SPECT/CT imaging: A systematic review.

Medical physics·2026
Same journal

Physics-constrained dual-domain network for CBCT reconstruction from orthogonal X-rays in gynecologic radiotherapy.

Medical physics·2026
Same journal

Decomposition-based harmonization for quantitative PET imaging across scanners and radiotracers.

Medical physics·2026
Same journal

Development and evaluation of an in vivo dose-based monitoring system for electron FLASH radiation therapy.

Medical physics·2026
See all related articles

Related Experiment Video

Updated: Nov 1, 2025

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
13:44

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns

Published on: August 30, 2013

43.1K

A signal detection model for quantifying overregularization in nonlinear image reconstruction.

Emil Y Sidky1, John Paul Phillips1, Weimin Zhou2

  • 1Department of Radiology, The University of Chicago, 5841 S. Maryland Ave., Chicago, IL, 60637, USA.

Medical Physics
|June 25, 2021
PubMed
Summary
This summary is machine-generated.

A new signal detection metric accurately quantifies fine image detail loss in nonlinear image reconstruction, unlike traditional RMSE. This method aids in optimizing breast CT parameters for better image quality.

Keywords:
CT image qualityimage reconstructionmodel observerstotal-variation

More Related Videos

Medical-grade Sterilizable Target for Fluid-immersed Fetoscope Optical Distortion Calibration
07:03

Medical-grade Sterilizable Target for Fluid-immersed Fetoscope Optical Distortion Calibration

Published on: February 23, 2017

7.8K
Cryo-Structured Illumination Microscopic Data Collection from Cryogenically Preserved Cells
11:55

Cryo-Structured Illumination Microscopic Data Collection from Cryogenically Preserved Cells

Published on: May 28, 2021

4.4K

Related Experiment Videos

Last Updated: Nov 1, 2025

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
13:44

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns

Published on: August 30, 2013

43.1K
Medical-grade Sterilizable Target for Fluid-immersed Fetoscope Optical Distortion Calibration
07:03

Medical-grade Sterilizable Target for Fluid-immersed Fetoscope Optical Distortion Calibration

Published on: February 23, 2017

7.8K
Cryo-Structured Illumination Microscopic Data Collection from Cryogenically Preserved Cells
11:55

Cryo-Structured Illumination Microscopic Data Collection from Cryogenically Preserved Cells

Published on: May 28, 2021

4.4K

Area of Science:

  • Medical Imaging
  • Computational Imaging
  • Signal Processing

Background:

  • Evaluating nonlinear image reconstruction quality is challenging, as standard metrics like Root Mean Square Error (RMSE) can promote over-regularization, obscuring subtle image details.
  • Existing metrics often fail to capture the loss of fine structures, leading to suboptimal parameter choices in image reconstruction algorithms.

Purpose of the Study:

  • To develop and validate a novel image quality metric for nonlinear image reconstruction based on signal detection.
  • To assess the proposed metric's ability to quantify the loss of fine image details, serving as a complement to global fidelity metrics like RMSE.

Main Methods:

  • A signal detection-based metric was developed, measuring signal detectability in both the sinogram and reconstructed images.
  • The metric was applied to breast CT simulations using a nonlinear total variation constrained least-squares (TV-LSQ) algorithm.
  • Image quality was evaluated using visual inspection, RMSE, and the new signal detection metric across varying acquisition parameters (number of views) and algorithm settings (constraint value, iterations).

Main Results:

  • The signal detection metric effectively correlated with visual assessments of over-regularization (blocky/patchy appearance) caused by TV-LSQ.
  • This trend contrasted with RMSE, which favored over-regularized images, indicating a limitation in capturing detail loss.
  • The proposed metric demonstrated its utility in identifying suboptimal parameter choices that lead to the loss of fine image details.

Conclusions:

  • A signal detection-based metric offers a valuable, complementary approach to RMSE for assessing image quality in nonlinear reconstruction.
  • This new metric provides a quantitative measure of fine detail loss, crucial for optimizing parameters in techniques like TV-LSQ.
  • Combining RMSE with the signal detection metric can guide the selection of CT algorithm and configuration parameters for improved nonlinear image reconstruction.