Surface Activity-Tuned Metal Oxide Chemiresistor: Toward Direct and Quantitative Halitosis Diagnosis
Hamin Shin1,2, Dong-Ha Kim1,2, Wonjong Jung3
1Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea.
Abstract:
Continuous monitoring of hydrogen sulfide (H2S) in human breath for early stage diagnosis of halitosis is of great significance for prevention of dental diseases. However, fabrication of a highly selective and sensitive H2S gas sensor material still remains a challenge, and direct analysis of real breath samples has not been properly attempted, to the best of our knowledge. To address the issue, herein, we introduce facile cofunctionalization of WO3 nanofibers with alkaline metal (Na) and noble metal (Pt) catalysts via the simple addition of sodium chloride (NaCl) and Pt nanoparticles (NPs), followed by electrospinning process. The Na-doping and Pt NPs decoration in WO3 grains induces the partial evolution of the Na2W4O13 phase, causing the buildup of Pt/Na2W4O13/WO3 multi-interface heterojunctions that selectively interacts with sulfur-containing species. As a result, we achieved the highest-ranked sensing performances, that is, response (Rair/Rgas) = 780 @ 1 ppm and selectivity (RH2S/REtOH) = 277 against 1 ppm ethanol, among the chemiresistor-based H2S sensors, owing to the synergistic chemical and electronic sensitization effects of the Pt NP/Na compound cocatalysts. The as-prepared sensing layer was proven to be practically effective for direct, and quantitative halitosis analysis based on the correlation (accuracy = 86.3%) between the H2S concentration measured using the direct breath signals obtained by our test device (80 cases) and gas chromatography. This study offers possibilities for direct, highly reliable and rapid detection of H2S in real human breath without the need of any collection or filtering equipment.
More Related Videos
09:15Iridium Oxide-reduced Graphene Oxide Nanohybrid Thin Film Modified Screen-printed Electrodes as Disposable Electrochemical Paper Microfluidic pH Sensors
Published on: November 22, 2016
11:18Manufacturing of a Nafion-coated, Reduced Graphene Oxide/Polyaniline Chemiresistive Sensor to Monitor pH in Real-time During Microbial Fermentation
Published on: January 7, 2019