Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
Published on: September 5, 2014
Gas Chromatography-Atmospheric Pressure Inlet-Mass Spectrometer Utilizing Plasma-Based Soft Ionization for the
Markus Weber1,2, Jan-Christoph Wolf2, Christoph Haisch1
1Department of Analytical Chemistry and Water Chemistry, Technical University of Munich, 81377 Munich, Germany.
Abstract:
Soft ionization by a chemical reaction in transfer (SICRIT) is applied to couple gas chromatography (GC) to a high-resolution atmospheric pressure inlet mass spectrometer. These instruments are generally used in combination with liquid chromatography systems (LC-MS). Ionization of alkanes is not possible here with conventional electrospray ionization. Alternatively, separate GC-electron ionization (EI)-MS is employed for the analysis of nonpolar substances like alkanes, however, with the inherent challenge of strong fragmentation. In the case of alkanes, the determination of molecular masses becomes nearly impossible in complex hydrocarbon mixtures because of the wealth of similar fragment ions and the absence of the molecular ion signal. SICRIT, a soft ionization technique based on dielectric barrier discharge (DBDI), produces characteristic oxidized cations from alkanes that can be directly correlated to their molecular mass. Isotope labeling experiments reveal an ionization mechanism via hydride abstraction and reaction with water. Soft ionization can be achieved for iso- and n-alkanes, with very little fragmentation, enabling the determination of their molecular mass. Calibrations for n-alkanes from C10 to C30 were performed exhibiting high linearity, reproducibility, and sensitivity with an average LOD of 69 pg (on column). Measurements of diesel fuel samples are compared to traditional GC-EI-MS. The presented method combines sensitivity and easy handling of a GC-EI-MS with the determination of molecular mass commonly only achieved with field ionization (FI)-MS, while using existing and highly optimized mass spectrometers commonly coupled with LC. Additionally, many other analytes such as (alkylated-) PAHs could be detected simultaneously in the diesel sample.
More Related Videos
08:10Fizzy Extraction of Volatile Organic Compounds Combined with Atmospheric Pressure Chemical Ionization Quadrupole Mass Spectrometry
Published on: July 14, 2017
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Detectors-II
Mass Spectrometry: Cycloalkane Fragmentation
For example, cyclohexane molecular ions have a mass-to-charge ratio (m/z) of 84, which tends to produce a stronger signal than linear alkanes like hexane. This stability comes from...