Related Experiment Video
Updated: Nov 1, 2025

Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
Published on: September 5, 2014
Identify low mass volatile organic compounds from cometary ice analogs using gas chromatography coupled to an
Thomas Javelle1, Michel Righezza1, Grégoire Danger2
1Aix-Marseille Université, Laboratoire de Physique des Interactions Ioniques et Moléculaires, UMR 7345, CNRS, Marseille, France.
Abstract:
Analysis of organic matter extracted from meteorites showed that solar system objects present an important molecular diversity. To improve our understanding of such organic matter, new analytical technologies must be developed. The present study displays the first experiments using a GC-FT-Orbitrap-MS to decipher the molecular diversity observed in experiments simulating the evolution of cometary ices. The proposed analytical strategy focuses on the analysis of 110 volatile organic compounds (VOC) with mainly 1 to 6 carbon atoms generated in such cometary ice analogs. Electron ionization (EI) and chemical ionization (CI) modes with methane (CH4) or ammonia (NH3) were optimized and compared. Those developments maximized the intensity of molecular, protonated or deprotonated ions, and improved high-resolution molecular formula unambiguous identification: EI mode is too energetic to provides there detection, while it is not the case in CI mode. Particularly, NH3 as a reagent gas improves amine identification in positive mode (PCI), and esters, alcohols, carbonyls, amides, carboxylic acids and nitriles in negative mode (NCI). The combination of both EI and CI mass spectrum analysis improves molecular identification, thanks to the detection of molecular, deprotonated or protonated ion of highest intensity and fragment formula assignments. The EI and NCI NH3 combination allows formula assignments up to 94% of our database with limit of detection up to 7 ppm. This procedure has been validated for untargeted GC-FT-Orbitrap-MS analysis of VOC coming from the processing of cometary ice analogs.
More Related Videos
08:10Fizzy Extraction of Volatile Organic Compounds Combined with Atmospheric Pressure Chemical Ionization Quadrupole Mass Spectrometry
Published on: July 14, 2017
09:49Identification of Olfactory Volatiles using Gas Chromatography-Multi-unit Recordings GCMR in the Insect Antennal Lobe
Published on: February 24, 2013
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Volatilization
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Spectrum: Interpretation
To...
Chemical Ionization (CI) Mass Spectrometry
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...