Blalock-Taussig Shunt versus Ductal Stent in the Palliation of Duct Dependent Pulmonary Circulation; A Systematic
Antoine Fakhry AbdelMassih1, Rahma Menshawey2, Esraa Menshawey2
1Pediatric Cardiology unit, Pediatrics' Department, Faculty of Medicine, Cairo University, Egypt.
Insights
Patent Ductus Arteriosus (PDA) stenting is a safer alternative to Blalock-Taussig (BT) shunts for infants needing palliative care. PDA stenting reduces mortality, complications, and ECMO use, improving patient outcomes.
Area of Science:
- Pediatric Cardiology
- Interventional Cardiology
- Neonatal Surgery
Background:
- Infants with ductal-dependent pulmonary blood flow require palliative procedures to establish circulation.
- Blalock-Taussig (BT) shunts and Patent Ductus Arteriosus (PDA) stents are common palliative interventions.
Purpose of the Study:
- To systematically review and meta-analyze studies comparing PDA stents and BT shunts.
- To evaluate the comparative efficacy and safety of these two palliative procedures.
Main Methods:
- Systematic review and meta-analysis conducted according to PRISMA guidelines.
- Comparative analysis of outcomes including mortality, complications, ECMO use, oxygen saturation, and Nakata index.
Main Results:
- PDA stenting group showed significantly reduced risk of mortality (RR=0.585, P=0.006) and complications (RR=0.523, P=0.011).
- Reduced risk of ECMO use (RR=0.267, P=0.008) and higher post-procedure oxygen saturation (SMD=1.307, P<0.001) were observed in the PDA stent group.
- Improved Nakata index (SMD=0.679, P<0.001) in the PDA stent group indicates better pulmonary artery development.
Conclusions:
- PDA stenting is a viable and safer alternative to the BT shunt procedure for palliation in infants with ductal-dependent pulmonary blood flow.
- PDA stenting offers better post-procedure stability and improved clinical outcomes compared to BT shunts.
Abstract:
In infants with ductal dependent pulmonary blood flow, Blalock-Taussig (BT) shunt and Patent Ductus Arteriosus (PDA) stent, are two palliative procedures aimed to restore circulation. A systematic review and metanalysis was performed on studies comparing PDA stents and BT shunts, in accordance with PRISMA guidelines. Meta-analysis revealed the following; (1) a reduced risk of mortality [RR = 0.585 [0.399-0.859], (P = 0.006)], (2) a reduced risk of complications [RR = 0.523 [0.318-0.860], (P = 0.011), and (3) a reduced risk of ECMO use [R = 0.267 [0.101-0.706] (P = 0.008)], all in the stent group. Additionally, stent group showed higher post procedure oxygen saturation [SMD = 1.307 [95% CI 1.065-1.550], (P < 0.001)], and Nakata index [SMD = 0.679 95% CI [0.513 to 0.845], (P < 0.001)]. PDA stenting presents a viable alternative to BT shunt procedure with better post procedure stability.
More Related Videos
09:31Hemodynamic Precision in the Neonatal Intensive Care Unit using Targeted Neonatal Echocardiography
Published on: January 27, 2023
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022