Related Experiment Video
Updated: Nov 1, 2025

Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Customized Two-Dimensional Computed Tomography-Guided Preoperative Pectus Bar Shaping
Christopher Wei Guang Ho1, Bien-Keem Tan1, Boon Hean Ong2
1From the Department of Plastic, Reconstructive and Aesthetic Surgery, Singapore General Hospital.
Introduction:
Successful minimally invasive repair of pectus excavatum relies on a pectus bar that closely conforms to the desired shape of the sternum and ribs to produce optimal elevation and remodeling. However, the present method of empirical intraoperative bar shaping is tedious and risks trauma to surrounding structures. To overcome this, we devised a technique using a life-sized computed tomography (CT) printout of the patient's chest wall to guide preoperative bar bending.
Methods:
A 5-cm-wide polymethylmethacrylate block placed on the sternum as the patient underwent chest CT was used as a marker to guide scaling of an axial screenshot of the patient's chest to life-size. This life-size image was printed and the planned correction of the patient's chest wall was traced onto it. The pectus bar was bent according to this template. Patient demographics, Haller index, surgical indications, operative technique, complications, aesthetic and functional improvements, and overall satisfaction were assessed.
Results:
Thirty patients (4 women) underwent primary minimally invasive repair of pectus excavatum with a single pectus bar shaped preoperatively over an 8-year period. The average age and Haller index was 20.6 years and 5.4, respectively. The mean operative time was 66.4 minutes. Satisfactory sternal elevation was attained with a single attempt at bar insertion in all cases. Two patients had pneumothoraxes that resolved without intervention. The mean follow-up period was 50.1 months. There were no cases of bar migration or recurrence of deformity after bar removal. On a 5-point Likert scale, all patients indicated an improvement in aesthetic appearance (4.6), and patients with physical symptoms (10) reported an improvement in function (4.4). The overall satisfaction score was 4.7.
Conclusions:
This technique of CT-guided preoperative pectus bar shaping is straightforward, eliminates the need for intraoperative revisions to bar shape, and achieves effective correction of the pectus excavatum deformity. All patients were satisfied with the aesthetic, functional, and overall outcomes.