Environmental semivolatiles and nonvolatiles analysis by hyphenated spectral techniques
D F Gurka1, L D Betowski, T L Jones
1Quality Assurance and Methods Development Division, U.S. Environmental Protection Agency, Las Vegas, Nevada 89114.
Abstract:
Environmental sample extracts contain a variety of volatile and nonvolatile organic compounds exhibiting a range of polarities and concentrations. Although gas chromatography/mass spectrometry (GC/MS) is the method of choice thus far for such analyses, this technique used alone cannot adequately characterize the volatiles in such samples and is not amenable to environmental nonvolatiles. A more complete characterization of environmental and hazardous waste samples is required to assess the dangers posed to the nation's groundwater by hazardous waste dumps. Online spectral confirmation by directly linked GC/Fourier transform infrared (FTIR)/MS is shown to provide useful structural information on environmental volatiles in hazardous wastes, even when the analyte's spectrum is not in either spectral database. This information can lead to biological-hazard estimation. The diffuse reflectance Fourier transform infrared (DRIFT) technique, used in conjunction with thermospray MS or fast atom bombardment (FAB) MS, provides confirmed identifications or confirmed compound class assignments of organic nonvolatiles in solid wastes. This is believed to be the first report of spectral confirmation (identification or functionality) of organic volatiles and nonvolatiles in environmental samples.
More Related Videos
08:23Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
08:49Multimodal Nonlinear Hyperspectral Chemical Imaging Using Line-Scanning Vibrational Sum-Frequency Generation Microscopy
Published on: December 1, 2023
Related Concept Videos
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Qualitative Analysis
There are two main approaches to qualitative analysis:...
High-Performance Liquid Chromatography: Types of Detectors
Atomic Emission Spectroscopy: Lab