Related Experiment Video
Updated: Oct 31, 2025
![An Automated Radiosynthesis of [68Ga]Ga-FAPI-46 for Routine Clinical Use](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F66708.jpg&w=3840&q=50)
An Automated Radiosynthesis of [68Ga]Ga-FAPI-46 for Routine Clinical Use
Published on: May 24, 2024
68Ga-FAPI-04 vs. 18F-FDG in a longitudinal preclinical PET imaging of metastatic breast cancer
Fan Ding1, Chen Huang2,3, Chenyi Liang1
1Department of Nuclear Medicine, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, 160 Pu Jian Rd., Shanghai , 200127, China.
Purpose:
This longitudinal study aims to evaluate the performance of 68 Ga-FAPI-04 and 18F-FDG and to profile the dynamic process of tumor metastasis in a preclinical 4T1 breast cancer model. Although both of these two radioligands are wildly used in clinic, no study was reported on their performance in the longitudinal monitoring of tumor metastasis. Also, no correlation between the expression level of fibroblast activation protein (FAP) and the development of tumor metastasis has been elucidated previously. In this study, we evaluated the performance of 68 Ga-FAPI-04 and 18F-FDG PET during the entire process of tumor metastasis, and their potential for the early diagnosis of tumor metastasis. We also clarified the correlation of uptakes as well as the signal-to-background (S/B) ratios between these two probes at different stages of tumor metastasis.
Methods:
Forty 4T1 metastatic breast cancer murine models were established using female BALB/c mice, followed by the longitudinal imaging with 68 Ga-FAPI-04 and 18F-FDG once a week for up to 6 weeks. In vitro hematoxylin and eosin (H&E) and immunochemistry (IHE) staining were performed to evaluate FAP expression on the metastatic lesions. Further statistical analysis was performed to evaluate the correlation of 68 Ga-FAPI-04 and 18F-FDG uptake (%ID/cc) at different stages of the metastasis.
Results:
68 Ga-FPAI-04 holds an advantage over 18F-FDG with higher sensitivity at the early stage of tumor metastasis. However, with the progress of tumor metastasis, uptake of 68 Ga-FAPI-04 decreases and becomes less sensitive than 18F-FDG. There is also no direct correlation between uptake or S/B ratios of 68 Ga-FAPI-04 and 18F-FDG during this dynamic process.
Conclusion:
68 Ga-FAPI-04 is more sensitive than 18F-FDG in detecting the early stage of tumor metastasis, but becomes less sensitive than 18F-FDG at the late stage of tumor metastasis. We envision this result would be meaningful for the explanation of the 68 Ga-FAPI-04 and 18F-FDG imaging both in the future clinic and preclinic studies.
More Related Videos
10:33Automated Preparation of [68Ga]Ga-3BP-3940 on a Synthesis Module for PET Imaging of the Tumor Microenvironment
Published on: April 25, 2025
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET