Transvaginal sonography determines accurately extent of infiltration of rectosigmoid deep endometriosis
M K Aas-Eng1,2,3, M Lieng3,4, B Dauser5
1Department of Gynecology, Oslo University Hospital, Oslo, Norway.
Objective:
To investigate the agreement of measurements of the three diameters of rectosigmoid deep endometriosis (DE) lesions between presurgical evaluation using transvaginal sonography (TVS) and postsurgical specimen measurement (PSM).
Methods:
This was a prospective observational multicenter study including symptomatic women undergoing surgical treatment for DE involving the rectosigmoid, by either discoid or segmental resection, from April 2017 to December 2019. TVS was performed presurgically to evaluate lesion size (craniocaudal-midsagittal length, anteroposterior thickness and transverse diameter), in accordance with the International Deep Endometriosis Analysis (IDEA) group consensus statement, and was compared with PSM. The agreement of lesion dimensions between the two methods was assessed by Bland-Altman plots and limits of agreement and additionally by the intraclass correlation coefficient (ICC) and Pearson's correlation coefficient. Systematic and proportional bias was assessed using the paired t-test.
Results:
A total of 207 consecutive women were eligible for inclusion. Forty-one women were excluded, leaving 166 women for final analysis. A total of 123 segmental resections and 46 discoid resections were performed (both procedures were performed in three women). The mean difference between TVS and PSM was 0.90 (95% CI, 0.85-0.95) mm for lesion length measurements, 1.03 (95% CI, 0.98-1.09) mm for lesion thickness measurements and 0.84 (95% CI, 0.79-0.89) mm for transverse diameter measurements. Bland-Altman analysis demonstrated good agreement between the two methods for measurements of lesion length. Furthermore, there was good reliability and correlation between TVS and PSM for lesion length measurements, as demonstrated by an ICC of 0.82 (95% CI, 0.75-0.87) and Pearson's correlation coefficient of 0.72 (95% CI, 0.62-0.80), moderate-to-good reliability and correlation for lesion thickness measurements, with an ICC of 0.76 (95% CI, 0.67-0.82) and Pearson's correlation coefficient of 0.61 (95% CI, 0.51-0.70), and poor-to-moderate reliability and correlation for transverse diameter measurements, with an ICC of 0.58 (95% CI, 0.39-0.71) and Pearson's correlation coefficient of 0.46 (95% CI, 0.33-0.58).
Conclusion:
Preoperative TVS determines accurately rectosigmoid DE lesion length. TVS can thereby contribute to optimal planning of surgical treatment options in women with rectosigmoid DE. © 2021 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
Related Concept Videos
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies VI: Voiding Cystourethrography and Cystography
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies


