Breathing irregularities before sleep onset on polysomnography in patients with heart diseases
Soshi Okamoto1, Masaki Ishii1, Shinichiro Hibi1
1Department of Geriatric Medicine, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.
Purpose:
Severe cardiac dysfunction can manifest with diurnal breathing irregularity. However, it remains to be clarified whether or not diurnal breathing irregularity is observed in patients with heart diseases, including relatively mild chronic heart failure (CHF), compared to those without heart diseases.
Methods:
In this cross-sectional study, consecutive inpatients who were admitted for evaluation of sleep-disordered breathing were enrolled. We extracted 3.5 min of stable respiratory signals before sleep onset using polysomnography, analyzed the airflow data using fast Fourier transform, and quantified breathing irregularities using Shannon entropy S.
Results:
A total of 162 subjects were evaluated. Among these, 39 subjects had heart diseases, including ischemic heart disease (IHD), atrial fibrillation (Af), CHF, and a history of aortic dissection. The values of Shannon entropy S of airflow signals in subjects with heart diseases were significantly higher than in those without heart diseases (p < 0.001). After excluding CHF, the Shannon entropy S was also significantly higher in subjects with heart diseases than in those without heart diseases (p < 0.001). The values of Shannon entropy S were significantly correlated with plasma brain natriuretic peptide levels (r = 0.443, p < 0.001). Although the values were also significantly correlated with body mass index, the presence of heart diseases was independently associated with breathing irregularity in the multiple logistic analysis. Matching analysis revealed consistent differences between subjects with heart diseases and without heart diseases.
Conclusion:
Breathing irregularity was observed before sleep onset in subjects with heart diseases who underwent polysomnography to diagnose sleep-disordered breathing.
More Related Videos
Related Concept Videos
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes...
Respiratory Volumes and Capacities I
Sleep Apnea
The condition is more prevalent among...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Acute Respiratory Failure-IV
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...