Related Experiment Video
Updated: Oct 31, 2025

Endotracheal Intubation Using a Flexible Intubation Endoscope as a Standardized Model for Safe Airway Management in Swine
Published on: August 25, 2022
Comparative evaluation of intubation performances using two different barrier devices used in the COVID-19 era: A
Ashish Kannaujia1, Rudrashish Haldar1, Rafat Shamim1
1Department of Anaesthesiology, Sanjay Gandhi Post Graduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India.
Background And Aims:
Protection of anaesthesiologists from contaminated aerosols of COVID 19 patients during endotracheal intubation has spurred the development of barrier devices like aerosol boxes and clear transparent plastic sheets and usage of videolaryngoscopes in COVID 19 patients. However, the efficiency, feasibility and difficulties faced by anaesthesiologist while performing endotracheal intubations under barrier devices require scientific validation. This manikin-based pilot study aims to assess the laryngoscopic performances of experienced anaesthesiologists under two different barrier enclosures.
Methods And Materials:
53 anaesthesiologists (14 Consultants and 39 Senior Residents) who were undergoing an airway training module as a part of preparedness for handling the COVID 19 pandemic were recruited. Using an aerosol box over a manikin, the participants attempted intubation using a Glidescope Videolaryngoscope and Macintosh laryngoscopes (GA and MA Groups). Subsequently, intubation was attempted under a transparent plastic sheet using both laryngoscopes (GP and MP groups). Time required for intubation, first pass success rates, subjective ease of intubation and the feedback obtained from the participants were recorded and analysed.
Results:
Time required for accomplishing successful intubation was 38.55 ± 12.16 seconds, 26.58 ± 5.73 seconds, 46.89 ± 15.23 seconds and 37.26 ± 8.71 seconds for GA, MA, GP and MP groups respectively. Time for intubation and difficulty (VAS) was least for Macintosh group with aerosol box (MA) and maximum time was taken in Glidescope group with transparent polythene drape (GP). First attempt success rate for Glidescope groups (GP and GA) were 100% and in MA and MP group was 98% and 96% respectively. Restriction in hand movement and stylet removal were the major difficulties reported.
Conclusion:
Longer intubation times were observed while using Glidescope Videolaryngoscopes with either of the two barrier devices in place compared to Macintosh laryngoscopes.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...

