Related Experiment Video
Updated: Oct 31, 2025

Whole-Body Nanoparticle Aerosol Inhalation Exposures
Published on: May 7, 2013
Experimental study on the control effect of different ventilation systems on fine particles in a simulated hospital
Xiangfei Kong1, Chenli Guo1, Zhang Lin2
1School of Energy and Environmental Engineering, Hebei University of Technology, Tianjin, China.
Abstract:
In recent years, a large number of respiratory infectious diseases (especially COVID-19) have broken out worldwide. Respiratory infectious viruses may be released in the air, resulting in cross-infection between patients and medical workers. Indoor ventilation systems can be adjusted to affect fine particles containing viruses. This study was aimed at performing a series of experiments to evaluate the ventilation performance and assess the exposure of healthcare workers (HW) to virus-laden particles released by patients in a confined experimental chamber. In a typical ward setting, four categories (top supply and exhaust, side supply and exhaust) were evaluated, encompassing 16 different air distribution patterns. The maximum reduction in the cumulative exposure level for HW was 70.8% in ventilation strategy D (upper diffusers on the sidewall supply and lower diffusers on the same sidewall return). The minimum value of the cumulative exposure level for a patient close to the source of the contamination pertained to Strategy E (upper diffusers on the sidewall supply and lower diffusers on the opposite sidewall return). Lateral ventilation strategies can provide significant guidance for ward operation to minimizing the airborne virus contamination. This study can provide a reference for sustainable buildings to construct a healthy indoor environment.
More Related Videos
Related Concept Videos
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation: