Related Experiment Video
Updated: Oct 31, 2025

Color Spot Test As a Presumptive Tool for the Rapid Detection of Synthetic Cathinones
Published on: February 5, 2018
Development and evaluation of a synthetic cathinone targeted gas chromatography mass spectrometry (GC-MS) method
Edward Sisco1, Amber Burns2, Arun S Moorthy1
1National Institute of Standards and Technology, Gaithersburg, MD, USA.
Abstract:
To address challenges associated with the increased prevalence of novel psychoactive substances (NPSs), laboratories often adopt new techniques or new methods with the goal of obtaining more detailed chemical information with a higher level of confidence. To demonstrate how new methods applied to existing techniques can be a viable approach, a targeted gas chromatography mass spectrometry (GC-MS) method for synthetic cathinones was developed. To create the method, a range of GC-MS parameters were first investigated using a seven-component test solution with the goal of minimizing compounds with overlapping acceptance windows by maximizing retention time differences within a reasonable runtime. Once developed, the targeted method was evaluated through several studies and was compared to a general GC-MS confirmatory method. The method produced a twofold increase in retention time differences of the test solution compounds with a 3.83-min shorter runtime than the general method. Limitations of the method were also studied by analyzing an additional forty-eight cathinones to identify instances where definitive compound identification may not be possible due to overlapping acceptance windows and mass spectra. Thirty-eight pairs of compounds had retention times differences of less than 2% and, of those thirty-eight, one pair had indistinguishable mass spectra. A set of case samples were also analyzed using the method to evaluate suitability for casework. An increase in split ratio was required to obtain acceptable sensitivity. The development of this method is part of a larger project to measure benefits and drawbacks of different drug chemistry workflows.
More Related Videos
10:13Author Spotlight: An Efficient Methodology to Confidently Differentiate and Characterize Fentanyl Analogs
Published on: November 8, 2024
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II