In vivopulse-echo measurement of apparent broadband attenuation andQfactor in cortical bone: a preliminary study
Jean-Gabriel Minonzio1,2,3, Chao Han1, Didier Cassereau1
1Sorbonne Université, INSERM UMR S 1146, CNRS UMR 7371, Laboratoire d'Imagerie Biomédicale, F-75006 Paris, France.
Abstract:
Quantitative ultrasound (QUS) methods have been introduced to assess cortical bone health at the radius and tibia through the assessment of cortical thickness (Ct.Th), cortical porosity and bulk wave velocities. Ultrasonic attenuation is another QUS parameter which is not currently used. We assessed the feasibility ofin vivomeasurement of ultrasonic attenuation in cortical bone with a broadband transducer with 3.5 MHz center frequency. Echoes from the periosteal and endosteal interfaces were fitted with Gaussian pulses using sparse signal processing. Then, the slope of the broadband ultrasonic attenuation (Ct.nBUA) in cortical bone and quality factorQ11-1were calculated with a parametric approach based on the center-frequency shift. Five human subjects were measured at the one-third distal radius with pulse-echo ultrasound, and reference data was obtained with high-resolution x-ray peripheral computed tomography (Ct.Th and cortical volumetric bone mineral density (Ct.vBMD)). Ct.Th was used in the calculation of Ct.nBUA whileQ11-1is obtained solely from ultrasound data. The values of Ct.nBUA (6.7 ± 2.2 dB MHz-1.cm-1) andQ11-1(8.6 ± 3.1%) were consistent with the literature data and were correlated to Ct.vBMD (R2=0.92,p<0.01, RMSE = 0.56 dB.MHz-1.cm-1, andR2=0.93,p<0.01, RMSE = 0.76%). This preliminary study suggests that the attenuation of an ultrasound signal propagating in cortical bone can be measuredin vivoat the one-third distal radius and that it provides an information on bone quality as attenuation values were correlated to Ct.vBMD. It remains to ascertain that Ct.nBUA andQ11-1measured here exactly reflect the true (intrinsic) ultrasonic attenuation in cortical bone. Measurement of attenuation may be considered useful for assessing bone health combined with the measurement of Ct.Th, porosity and bulk wave velocities in multimodal cortical bone QUS methods.
More Related Videos
Related Concept Videos
Pulse Assessment Sites
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: