Objective:
To compare the shear bond strength (SBS) after thermocycling of four universal adhesives applied in self-etch mode on dentin and etch-and-rinse mode on enamel.
Study Design:
Flat 144 buccal or lingual dentin and enamel surfaces from 72 non-carious primary molars were prepared. Samples were segregated into 12 groups (n=12): Adper Single Bond 2 etch-and-rinse (SB_T) and Clearfil SE Bond self-etch (SE_S) applied to enamel and dentin served as controls. Scotch Bond Universal Adhesive (SBU), Clearfil S3 Bond Universal Adhesive (SEU), Tetric N-Bond Universal Adhesive (TEN), and All Bond Universal (BIS) were applied in etch-and-rinse mode to enamel and in self-etch mode to dentin. They were thermocycled for 5000 cycles. SBS testing and the evaluation of fracture mode were performed.
Results:
SB_T showed statistically higher SBS than other adhesive groups using etch-and-rinse mode on enamel. SE_S and BIS had statistically higher SBS than other adhesive groups using self-etch mode on dentin. Mixed failure was the most common failure mode in each group.
Conclusion:
The universal adhesives did not show higher SBS than SB_T when using etch-and-rinse on enamel. All universal adhesives showed higher SBS than SB_T and had SBS similar to SE_S, except SBU when using self-etch mode on dentin.