Workflow Based on the Combination of Isotopic Tracer Experiments to Investigate Microbial Metabolism of Multiple Nutrient Sources
Published on: January 22, 2018
AccuCor2: isotope natural abundance correction for dual-isotope tracer experiments
Yujue Wang1,2, Lance R Parsons3, Xiaoyang Su4,5
1Department of Medicine, Rutgers-Robert Wood Johnson Medical School, New Brunswick, NJ, USA.
Abstract:
Stable isotope labeling techniques have been widely applied in the field of metabolomics and proteomics. Before the measured mass spectral data can be used for quantitative analysis, it must be accurately corrected for isotope natural abundance and tracer isotopic impurity. Despite the increasing popularity of dual-isotope tracing strategy such as 13C-15N or 13C-2H, there are no accurate tools for correcting isotope natural abundance for such experiments in a resolution-dependent manner. Here, we present AccuCor2 as an R-based tool to perform the correction for 13C-15N or 13C-2H labeling experiments. Our method uses a newly designed algorithm to construct the correction matrices that link labeling pattern and measured mass fractions, then use non-negative least-squares to solve the labeling patterns. Our results show that the dual-isotope experiments often require a mass resolution that is high enough to resolve 13C and 15N or 13C and 2H. Otherwise, the labeling pattern is not solvable. However, this mass resolution may not be sufficiently high to resolve other non-tracer elements such as oxygen or sulfur from the tracer elements. Therefore, we design AccuCor2 to perform the correction based on the actual mass resolution of the measurements. Using both simulated and experimental data, we show that AccuCor2 performs accurate and resolution-dependent correction for dual-isotope tracer data.
Related Concept Videos
Mass Spectrometry: Isotope Effect
Isotopes and Radioisotopes
An isotope containing...
Isotopes
An element's atomic mass, or weight,...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...