Related Experiment Video
Updated: Oct 31, 2025

05:57
A Teleoperated Robotic System-Assisted Percutaneous Transiliac-Transsacral Screw Fixation Technique
Published on: January 6, 2023
3.1K
A Simple Modified Technique for In-Situ Screw Fixation in Slipped Capital Femoral Epiphysis
K Venkatadass1, V Durga Prasad1, Chirag Parsana1
1Department of Orthopaedics and Spine Surgery, Ganga Hospital, 313, Mettupalayam Main Road, Coimbatore, Tamilnadu India.
Indian Journal of Orthopaedics
|July 1, 2021
Summary
This study presents a modified in-situ pinning technique for slipped capital femoral epiphysis (SCFE), demonstrating improved safety and accuracy. The modified screw fixation method on a radiolucent table resulted in no major complications in 60 hips.
Area of Science:
- Orthopedic surgery
- Pediatric orthopedics
- Skeletal imaging
Background:
- In-situ pinning is a standard treatment for slipped capital femoral epiphysis (SCFE).
- Existing techniques carry inherent complications.
- A modified in-situ screw fixation technique on a radiolucent table is proposed to mitigate these risks.
Purpose of the Study:
- To describe and evaluate a modified in-situ screw fixation technique for SCFE.
- To assess the safety and accuracy of this modified technique.
- To compare outcomes with existing methods.
Main Methods:
- Analysis of 60 consecutive hips undergoing modified in-situ fixation for SCFE or prophylactic fixation.
- Categorization of femoral head into three zones (A, B, C) for screw placement analysis.
- Measurement of screw angle and tip-to-articular surface distance in AP and lateral views.
- Assessment of interobserver agreement and complications at minimum one-year follow-up.
Main Results:
- Over 91% of screws were placed in zone-A (central) in both AP and lateral views.
- No screws were placed in zone-C (peripheral).
- Average screw deviation was <15° (AP) and <7° (lateral).
- Mean screw tip to articular margin distance was 5.15 mm (AP) and 6.15 mm (lateral).
- High interobserver agreement (0.8) and no intraoperative or postoperative complications (avascular necrosis, chondrolysis, etc.) were observed.
Conclusions:
- Modified in-situ pinning on a radiolucent table is a safe and advantageous procedure for SCFE.
- This technique enhances the safety and accuracy of screw fixation.