Rapid Scan Electron Paramagnetic Resonance Opens New Avenues for Imaging Physiologically Important Parameters In Vivo
Published on: September 26, 2016
High fidelity triangular sweep of the magnetic field for millisecond scan EPR imaging
Denis A Komarov1, Alexandre Samouilov1, Hiroshi Hirata2
1The EPR Center and Department of Internal Medicine, Division of Cardiovascular Medicine, Davis Heart and Lung Institute, The Ohio State University College of Medicine, Columbus, OH 43210, USA.
Abstract:
Linearity of the magnetic field sweep is important for high resolution continuous wave EPR imaging. Driving the field with triangular wave function is the most efficient way to scan EPR projections. However, the magnetic field sweep profile can be significantly distorted during fast millisecond projection scan. In this work, we introduce a method to generate highly linear and properly symmetrical triangular sweeps of the magnetic field using calibrated harmonics of the triangular wave function. First, the frequency response function of the EPR magnet and its power circuitry was obtained. For this, the field sweeping coil was driven with sinusoidal signals of different frequencies and the actual magnetic field inside the magnet was recorded. To cover wide range of frequencies, the measurements were carried out independently using gaussmeter, Hall-effect linear sensor integrated circuit, and an inductance coil. For each frequency, the system gain and the phase delay were determined. These data were used to adjust the amplitudes and the phases of individual harmonics of the triangular wave function. After the calibration, the maximum deviation of the magnetic field from the linear function was 0.05% of sweep width for 4 ms scan. The maximum discrepancy between the forward and the reverse scan was less than 0.04%. Sweep overhead time for changing the scan direction was 5%. The proposed approach allows generation of high fidelity triangular magnetic field sweeps with accuracy better than 0.1% for the range of the magnetic field sweep widths up to 48 G and scan duration from 10 s down to 1 ms.
Related Concept Videos
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
NMR Spectrometers: Resolution and Error Correction
Atomic Nuclei: Magnetic Resonance
NMR Spectrometers: Overview
Two-Dimensional (2D) NMR: Overview
The first step is the preparation period, during which nucleus A is excited with a radiofrequency pulse....
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...