Related Experiment Video
Updated: Oct 30, 2025

Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Change of Mechanical Properties of Repair Mortars after Frost Resistance Rests
Grażyna Łagoda1, Tomasz Gajda2
1Department of Bridges, Faculty of Civil Engineering, Institute of Roads & Bridges, Warsaw University of Technology, Al. Armii Ludowej 16, 00-637 Warsaw, Poland.
Abstract:
The use of repair mortars for concrete structures repair with no or limited resistance to the impact caused by freeze and thaw cycles is often the primary repair failure cause. This is particularly important in Poland. Due to the geographical location of the country, there is a large temperature difference between summer and winter. The number of passes through the threshold temperature of 0 °C throughout the year in the winter season exceeds 100. The article presents a comparison of the frost resistance results of tests of repair mortars. The first method was performed according to the Polish Guidelines (without the use of de-icing salts) and the second method according to PN-EN 1504-3 (with the use of de-icing salts). The results obtained were inconsistent in many areas. In particular, significant differences in the results for the change in compressive strength and the change in bending strength were observed. In the case of the frost resistance testing without the use of de-icing salts, a decrease in compressive strength was usually accompanied by a decrease in bending strength. In the case of frost resistance tests with the use of de-icing salts, an increase in the bending strength of mortars was observed (even by a dozen or so percent) with a decrease in the compressive strength of mortars (even by several dozen percent).
More Related Videos
06:27Sandy Soil Improvement through Microbially Induced Calcite Precipitation MICP by Immersion
Published on: September 12, 2019
07:15A Testing Platform for Durability Studies of Polymers and Fiber-reinforced Polymer Composites under Concurrent Hygrothermo-mechanical Stimuli
Published on: December 11, 2014
Related Concept Videos
Mortar Properties
Frost Resistant Concrete
Introducing microscopic air bubbles into the concrete mix through air entrainment creates small voids that accommodate ice expansion, thereby reducing internal pressures and preventing cracking. The optimal amount of...
Frost Action on Concrete
This freeze-thaw cycle primarily causes surface scaling, where...
Masonry in Cold and Hot Weather Conditions
Other key practices include keeping masonry units...
Mortar Joint Deterioration in Masonry
The...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...