Percutaneous liver biopsy and track embolization with steel coils
1Department of Diagnostic Radiology, Royal Postgraduate Medical School, Hammersmith Hospital, London, England.
Radiology
|October 1, 1988
Abstract:
Eight patients with liver disease and seriously abnormal blood coagulation underwent biopsy of the liver performed through a percutaneously introduced sheath, followed by embolization of the biopsy track with steel coils. In all cases the biopsy procedure produced profuse bleeding through the sheath. However, the bleeding ceased within a few minutes after coil insertion.