Related Experiment Video
Updated: Oct 30, 2025

A Bedside, Single Burr Hole Approach to Multimodality Monitoring in Severe Brain Injury
Published on: March 26, 2019
External Validation and Calibration of the DecaPreT Prediction Model for Decannulation in Patients with Acquired
Elio Leto1, Danilo Lofaro2, Lucia Francesca Lucca1
1S. Anna Institute and Research in Advanced Neurorehabilitation (RAN), 88900 Crotone, Italy.
Abstract:
We propose a new set of clinical variables for a more accurate early prediction of safe decannulation in patients with severe acquired brain injury (ABI), during a post-acute rehabilitation course. Starting from the already validated DecaPreT scale, we tested the accuracy of new logistic regression models where the coefficients of the original predictors were reestimated. Patients with tracheostomy were retrospectively selected from the database of the neurorehabilitation unit at the S. Anna Institute of Crotone, Italy. New potential predictors of decannulation were screened from variables collected on admission during clinical examination, including (a) age at injury, (b) coma recovery scale-revised (CRS-r) scores, and c) length of ICU period. Of 273 patients with ABI (mean age 53.01 years; 34% female; median DecaPreT = 0.61), 61.5% were safely decannulated before discharge. In the validation phase, the linear logistic prediction model, created with the new multivariable predictors, obtained an area under the receiver operating characteristics curve of 0.901. Our model improves the reliability of simple clinical variables detected at the admission of the post-acute phase in predicting decannulation of ABI patients, thus helping clinicians to plan better rehabilitation.