Jove
Visualize
Contact Us

Related Experiment Videos

Balloon embolectomy catheter shear force gauge.

A K Chin1, S Y Monfort, T J Fogarty

  • 1Department of Surgery, Sequoia Hospital, Redwood City, California.

Surgery, Gynecology & Obstetrics
|October 1, 1988
PubMed
Summary

Surgeons can now feel shear force during arterial procedures using a new gauge. This device aims to reduce complications associated with balloon embolectomy catheters.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

1kW fiber-coupled pump-module at 976nm with 50% efficiency.

Optics express·2017
Same author

Monitoring Distal Extremity Perfusion with the Pulse Amplitude Monitor during Vascular Reconstruction.

Surgical technology international·2015
Same author

Selected applications of balloon dissection.

Surgical technology international·2011
Same author

Extraperitoneal laparoscopic hernia repair: experience in 178 patients.

Surgical technology international·2011
Same author

Keyhole technique for autologous brachiobasilic transposition arteriovenous fistula.

Journal of vascular surgery·2005
Same author

Aortoiliac angulation and the need for secondary procedures to secure stent graft fixation: which angle is important?

International angiology : a journal of the International Union of Angiology·2003
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Area of Science:

  • Vascular surgery
  • Biomedical engineering
  • Surgical instrumentation

Background:

  • Balloon embolectomy is a common procedure for clearing arterial blockages.
  • Current methods lack tactile feedback for shear force, potentially leading to endothelial damage.
  • Shear force-related complications can negatively impact patient outcomes.

Purpose of the Study:

  • To introduce a novel shear force gauge for use in balloon embolectomy.
  • To enhance surgical training by providing tactile feedback on arterial wall forces.
  • To reduce the incidence of shear force-induced complications during the procedure.

Main Methods:

  • Development of a specialized shear force gauge integrated with embolectomy catheters.
  • Utilizing the device to provide real-time feedback to surgeons during simulated or actual procedures.
  • Assessing the gauge's ability to convey the magnitude of shear force exerted on the endothelium.

Main Results:

  • The shear force gauge successfully allows surgeons to perceive the forces applied during balloon embolectomy.
  • Provides a quantifiable measure of shear force, aiding in procedural control.
  • Potential for improved surgical technique and reduced endothelial trauma.

Conclusions:

  • The shear force gauge serves as a valuable teaching tool for surgeons.
  • It is expected to decrease complications linked to excessive shear force in balloon embolectomy.