Related Experiment Video
Updated: Oct 30, 2025

A Microfluidic-based Electrochemical Biochip for Label-free DNA Hybridization Analysis
Published on: September 10, 2014
Cobalt Phthalocyanine-Ionic Liquid Composite Modified Electrodes for the Voltammetric Detection of DNA Hybridization
Ece Yaralı1,2, Arzum Erdem1,2
1Department of Analytical Chemistry, Faculty of Pharmacy, Ege University, Bornova, Izmir 35100, Turkey.
Abstract:
In this study, cobalt phthalocyanine (CoPc) and ionic liquid (IL) modified pencil graphite electrodes (PGEs) were designed and implemented to detect sequence-selective DNA hybridization related to the Hepatitis B virus (HBV). The surface characterization of CoPc-IL-PGEs was investigated by scanning electron microscopy (SEM), and the electrochemical behavior of electrodes were studied by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) techniques. The voltammetric detection of hybridization was investigated by evaluating the guanine oxidation signal, measured by differential pulse voltammetry (DPV) technique. The implementation of our biosensor to serum samples was also examined using fetal bovine serum (FBS). The detection limit was established as 0.19 µg/mL in phosphate buffer solution (PBS) (pH 7.40) and 2.48 µg/mL in FBS medium. The selectivity of our assay regarding HBV DNA hybridization in FBS medium was tested in the presence of other DNA sequences. With this aim, the hybridization of DNA probe with non-complementary (NC) or mismatched DNA sequence (MM), or in the presence of mixture samples containing DNA target NC (1:1) or DNA target MM (1:1), was studied based on the changes in guanine signal.