Related Experiment Video
Updated: Oct 30, 2025

08:51
The Use of Thermal Infra-Red Imaging to Detect Delayed Onset Muscle Soreness
Published on: January 22, 2012
19.5K
Palm Temperature Differences after Static and Dynamic Load on High Bar
Karmen Šibanc1, Ivan Čuk1, Maja Pajek1
1Faculty of Sport, University of Ljubljana, SI-1000 Ljubljana, Slovenia.
Sensors (Basel, Switzerland)
|July 2, 2021
Summary
Palm temperature in athletes significantly drops after exercise, then rises above pre-exercise levels. Static loads stabilize hand temperature faster than dynamic loads, indicating different recovery patterns.
Area of Science:
- Sports Science
- Biophysics
- Thermal Imaging Applications
Background:
- Limited research exists on palm temperature responses to exercise.
- Understanding hand temperature changes is crucial for preventing injuries like blisters.
Purpose of the Study:
- To investigate palm temperature variations in human hands after static (Hang) and dynamic (Swing in Hang) loads.
- To analyze the recovery patterns of palm temperature post-exercise.
Main Methods:
- Utilized high-quality thermal imaging to measure palm temperatures in 38 sports science students.
- Recorded temperatures before, immediately after, and for 5 minutes post-load (30s duration) across nine regions of interest.
- Analyzed mean, standard deviation, and pixel data for temperature changes.
Main Results:
- No significant difference was found between left and right hand palm temperatures.
- Immediately post-load, palm temperature decreased significantly, then increased above pre-load levels.
- Static loads resulted in a stabilized elevated temperature after 3 minutes, while dynamic loads showed continuous temperature increase.
Conclusions:
- Both static and dynamic loads induce significant transient changes in palm temperature.
- Recovery dynamics differ between static and dynamic loading, with static loads reaching a plateau faster.
- Further research is needed to determine the full recovery time course for palm temperature.
Related Concept Videos
Assessing Body Temperature - Axilla
849
Procedural Guide for Assessing Axillary Body Temperature using a Digital Thermometer:
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
849
Assessing Body Temperature - Temporal Artery
765
Here is a stepwise guide to assessing the body temperature at the temporal artery using a temporal artery thermometer
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
765
Thermal Stress
2.8K
If the temperature of an object is changed while it is prevented from expanding or contracting, the object is subjected to stress. The stress is compressive if the object expands in the absence of constraint and tensile if it contracts. This stress resulting from temperature change is known as thermal stress. It can be quite large and can cause damage. To avoid this stress, engineers may design components so they can expand and contract freely. For instance, on highways, gaps are deliberately...
2.8K
Temperature Dependent Deformation
245
In a nonhomogeneous rod made up of steel and brass, restrained at both ends and subjected to a temperature change, several steps are involved in calculating the stress and compressive load. Due to the problem's static indeterminacy, one end support is disconnected, allowing the rod to experience the temperature change freely. Next, an unknown force is applied at the free end, triggering deformations in the rod's steel and brass portions. These deformations are then calculated and added...
245
Static and Kinetic Frictional Force
20.2K
One of the simpler characteristics of sliding friction is that it is parallel to the contact surfaces between systems, and is always in a direction that opposes the motion or attempted motion of the systems relative to each other. If two systems are in contact and moving relative to one another, then the friction between them is called kinetic friction. For example, kinetic friction slows a hockey puck sliding on ice.
However, if two systems are in contact and are stationary relative to one...
However, if two systems are in contact and are stationary relative to one...
20.2K
Thermal expansion and Thermal stress: Problem Solving
1.5K
San Francisco's Golden Gate Bridge is exposed to temperatures ranging from -15 °C to 40 °C. At its coldest, the main span of the bridge is 1275 m long. Assuming that the bridge is made entirely of steel, what is the change in its length between these temperatures?
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in...
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in...
1.5K