Related Experiment Video
Updated: Oct 30, 2025

Facile Preparation of 4-Substituted Quinazoline Derivatives
Published on: February 15, 2016
Thermal (In)stability of Atropine and Scopolamine in the GC-MS Inlet
Gordana Koželj1, Helena Prosen2
1Institute of Forensic Medicine, Faculty of Medicine, University of Ljubljana, Korytkova 2, SI-1000 Ljubljana, Slovenia.
Abstract:
The intoxication due to unintentional or intentional ingestion of plant material containing tropane alkaloids is quite frequent. GC-MS method is still widely used for the identification of these toxicologically important substances in human specimen. During general unknown analysis, high temperature of inlet, at least 270 °C, is commonly used for less volatile substances. Unfortunately, both tropanes are thermally unstable and could be overlooked due to their degradation. The temperature-related degradation of tropanes atropine and scopolamine was systematically studied in the inlet of a GC-MS instrument in the range 110-250 °C by increments of 20 °C, additionally also at 275 °C, and in different solvents. At inlet temperatures not higher than 250 °C, the degradation products were formed by elimination of water and cleavage of atropine's ester bond. At higher temperatures, elimination of formaldehyde became predominant. These phenomena were less pronounced when ethyl acetate was used instead of methanol, while n-hexane proved unsuitable for several reasons. At an inlet temperature of 275 °C, tropanes were barely detectable. During systematic toxicological analysis, any tropanes' degradation products should indicate the possible presence of atropine and/or scopolamine in the sample. It is not necessary to prepare thermally stable derivatives for confirmation. Instead, the inlet temperature can be decreased to 250 °C, which diminishes their degradation to a level where their detection and identification are possible. This was demonstrated in several case studies.
More Related Videos
09:36Author Spotlight: Discovering New Alkaloids in Plants with Advanced Mass Spectrometry Techniques
Published on: March 8, 2024
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Cholinergic Antagonists: Pharmacokinetics
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...