Related Experiment Video
Updated: Oct 30, 2025

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Effect of Different Resin Cements on the Bond Strength of Custom-made Reinforced Glass Fiber Posts-A Push-out Study
Patrícia Mc Soares1, Luis Fsa Morgan2, Stéphanie Q Tonelli1
1Department of Dentistry, Pontifical Catholic University of Minas Gerais, Belo Horizonte, Minas Gerais, Brazil.
Aim And Objective:
This study aims to evaluate the effect of different resin cements on the bond strength (BS) of custom-made glass fiber posts (GFPs) using the push-out test.
Materials And Methods:
Twenty-four uniradicular bovine teeth were selected. The crowns were sectioned at the cementoenamel junction, and the root canals were treated. The post spaces of the teeth were prepared to a length of 12 mm to receive a GFP. The specimens were randomly assigned to three experimental groups (n = 8), according to the resin cement used to fix the GFPs: RelyX U200 (U200), Allcem Core (ACC), and Allcem Dual (ACD). Each specimen was sectioned into six slices per root third (cervical, middle, and apical), which were subjected to the push-out test. BS values were calculated and compared using the Kruskal-Wallis and Friedman tests.
Results:
There were significant differences in the middle third, according to the resin cement type used (p < 0.05). ACD showed lower BS values (p < 0.05). Significant differences were observed for ACD among the thirds of the slices, with the lowest values also observed for the middle third (p < 0.05).
Conclusion:
The present study shows that ACC and U200 showed higher BS values compared with ACD, and were also less influenced by the depth of the root dentin.
Clinical Significance:
The restoration of endodontically treated teeth is a challenge in dentistry, and, in most cases, will require installation of fiberglass pins. In this respect, several types of resin cements are indicated for cementation of these pins; for this reason, their adhesiveness must be adequately investigated. Conventional cements and self-adhesive cements have shown satisfactory performance in cementing the custom-made GFPs, thereby making these cements satisfactory clinical choices. The present study suggests that ACD had lower performance than the other two cements evaluated.
Related Concept Videos
Bonding and Strength of Aggregate
Fiber Reinforced Concrete
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Reinforcements in Concrete
Impact Strength of Concrete

