Published on: January 12, 2017
Use of ultrasound imaging software to differentiate venous and lymphatic edema in lower limbs
Vanessa Lôbo de Carvalho1, Guilherme Benjamin Brandão Pitta1, Sérgio Xavier Salles Cunha2
1Universidade Estadual de Ciências da Saúde de Alagoas - UNCISAL, Departamento de Cirurgia, Maceió, AL, Brasil.
Background:
Lower limb edema has both systemic and local causes. Using software to differentiate the origin of edema in ultrasound images is an innovation.
Objective:
To determine the parameters for using software to differentiate edema of venous and/or lymphatic origin in ultrasound images of the lower limbs.
Method:
This is a cross-sectional, quantitative, analytical study with non-probabilistic sampling by convenience. Data were collected by patient interview, physical examination, ultrasound examination, and analysis of software for tissue characterization in ultrasound image by means of quantification of echogenicity and Gray Scale Median (GSM).
Results:
The sample comprised 42 lower limbs with venous edema, 35 with lymphatic edema, 14 with mixed edema, and 11 control limbs. The distributions of pixels in echogenicity intervals by group was as follows. In the venous edema group, 88.31% were distributed from hypoechogenic interval IV to echogenic interval III; in the lymphatic edema group 71.73% were from hypoechogenic interval II to echogenic interval I; in the mixed edema group 76.17% were from hypoechogenic interval III to echogenic interval II; and in the control group 84.87% were distributed from echogenic interval II to hyperechogenic interval I. Mean and standard deviation of GSM values showed statistical differences between groups.
Conclusion:
The CATUS software enabled differentiation of the type of lower limb edema, facilitating diagnosis of edema type and, consequently, choice of the best therapeutic option.
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Imaging Studies II: Ultrasonography
Varicose Veins II: Diagnostic Studies and Interprofessional Care
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):