Purpose:
To evaluate effect of virtual monoenergetic reconstruction on contrast-enhanced abdominal CT obtained using a dual-layer detector CT (DLCT) in patients with arms-down positioning, in comparison with conventional 120-kVp image.
Methods:
A total of 162 consecutive patients who underwent abdominal CT scans using a DLCT with arms-down positioning were retrospectively enrolled. 120-kVp image and virtual monoenergetic images (VMIs) at 40-100 keV were compared for arm-induced artifact reduction capability and image quality through objective and subjective assessments. Diagnostic performance was compared between VMI with the best quality and 120-kVp image.
Results:
VMIs at 60-100 keV showed significantly lower (p < 0.001) artifact index than 120-kVp image. Subjective severity of arm-induced streak artifacts was significantly (p < 0.001) lower in VMIs at 70-100 keV than in 120-kVp image. CNRs measured in artifact and reference areas were superior (p < 0.05) in 40-70 keV to those in 120 kVp. Overall image quality was superior (p < 0.05) in 60-90 keV to 120 kVp. 70-keV VMI was chosen as the best image by two independent readers. In ROC analysis of lesion detection in the liver, spleen, and kidneys, the AUC was significantly higher for 70-keV VMI (reader 1, 0.962; p = 0.011; reader 2, 0.981; p = 0.012) than that for 120-kVp image (reader 1, 0.891; reader 2, 0.922).
Conclusion:
The70-keV VMI from DLCT could improve abdominal CT images by reducing streak artifacts and increasing image contrast in patients who could not elevated their arms. The 70-keV VMI showed better diagnostic performance than the conventional 120 kVp image.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
06:33Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Radiological Investigation I: X-ray and CT
Ultrasonography