Related Experiment Video
Updated: Oct 30, 2025

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
Published on: February 19, 2021
Safety of active auditory implants in magnetic resonance imaging
Guy Fierens1,2,3, Nina Standaert4, Ronald Peeters5
1Laboratory of Soft Matter and Biophysics, Department of Physics and Astronomy, KU Leuven, Celestijnenlaan 200D, B-3001, Heverlee, Belgium.
Abstract:
Magnetic resonance imaging (MRI) has become the gold standard for the diagnosis of many pathologies. Using MRI in patients with auditory implants can however raise concerns due to mutual interactions between the implant and imaging device, resulting in potential patient risks. Several implant manufacturers have been working towards more MRI safe devices. Older devices are however often labelled for more stringent conditions, possibly creating confusion with patients and professionals. With this myriad of different devices that are implanted in patients for lifetimes of at least 20 years, it is crucial that both patients and professionals have a clear understanding of the safety of their devices. This work aims at providing an exhaustive overview on the MRI safety of active auditory implants. The available industry standards that are followed by manufacturers are outlined and an overview of the latest scientific developments focusing on the last five years is provided. In addition, based on the analysis of the adverse events reported to the Food and Drug Administration (FDA) and in literature within the past ten years, a systematic review of the most commonly occurring issues for patients with auditory implants in the MRI environment is provided. Results indicate that despite the release of more MRI conditional active hearing implants on the market, adverse events still occur. An extensive overview is provided on the MRI safety of active auditory implants, aiming to increase the understanding of the topic for healthcare professionals and contribute to safer scanning conditions for patients.
More Related Videos
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
10:09Mapping the After-effects of Theta Burst Stimulation on the Human Auditory Cortex with Functional Imaging
Published on: September 12, 2012
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...