Echocardiographic Evaluation of Atrial Communications before Transcatheter Closure
Published on: February 8, 2022
Hemodynamic changes during transcatheter atrial septal defect closure predict midterm heart failure deterioration in
Hiroyuki Yamamoto1, Toshiro Shinke1,2, Hiromasa Otake1
1Division of Cardiovascular Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan.
Objectives:
To investigate whether hemodynamic changes during balloon occlusion test (BOT) predict future heart failure (HF) deterioration after transcatheter atrial septal defect closure (tASD-closure).
Background:
Midterm HF deterioration can sometimes occur after tASD-closure in adults. Whether hemodynamic changes during tASD-closure can help identify patients at risk is unknown.
Methods:
This prospective observational study enrolled 86 consecutive adult patients who underwent tASD-closure. Hemodynamic parameters, including pulmonary capillary wedge pressure (PCWP), were measured at baseline, during BOT, and after tASD-closure. The changes in PCWP during BOT and after tASD-closure were defined as ΔPCWP (Occ-Pre) and ΔPCWP (Post-Pre), respectively. Clinical parameters were evaluated before tASD-closure and during the 3-month follow-up. We assessed the occurrence of HF deterioration (HF requiring hospitalization or additional diuretics) during a 2-year follow-up period and categorized patients into HF (+) and HF (-) groups accordingly. The aforementioned parameters were compared between groups.
Results:
Midterm HF deterioration occurred in 12 patients (13.9%). Compared to the HF (-) group, the HF (+) group presented a significantly higher ΔPCWP (Occ-Pre) (9.5 ± 4.4 mmHg vs. 3.0 ± 3.3 mmHg; p < 0.001) and ΔPCWP (Post-Pre) (4.0 ± 2.8 mmHg vs. 0.6 ± 1.8 mmHg; p = 0.004). Receiver operating characteristic curve analysis showed that the ΔPCWP (Occ-Pre) cutoff value of 5.5 mmHg had excellent ability to predict HF deterioration (Area under the curve 0.886 [0.779-0.993], p < 0.001; sensitivity 0.917, specificity 0.824).
Conclusions:
Increases in PCWP during BOT predict midterm HF deterioration after tASD-closure. Close surveillance may be needed in patients with a ΔPCWP (Occ-Pre) >5 mmHg.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
08:19Transthoracic Echocardiography to Assess Post-Resuscitation Left Ventricular Dysfunction After Acute Myocardial Infarction and Cardiac Arrest in Pigs
Published on: July 12, 2022
Related Concept Videos
Heart Failure II: Pathophysiology
Mitral Regurgitation I: Introduction
Mitral Stenosis I: Introduction
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Pathophysiology of Heart Failure
Heart Failure VI: Adjunct Therapies