Related Experiment Video
Updated: Oct 29, 2025

In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
MIBG cardiac imaging compared to ejection fraction in evaluation of cardiotoxicity: a systematic review
Thaís Rossato Arrais1,2, Germano Dallegrave Cavalli3, Bárbara Tietbohl Dos Santos4
1Nuclear Medicine Department, Hospital Moinhos de Vento, Rua Ramiro Barcelos, 910-201, Porto Alegre, RS, 90035-001, Brazil. thaisarrais@hotmail.com.
Background:
Advances in diagnosis and treatment of cancer has improved survival but resulted in increased cardiotoxic effects. The decrease in left ventricular ejection fraction (EF), one of the pillars of diagnosis of cardiotoxicity, seems to be a late process in the evolution of the disease, so 123I-metaiodobenzylguanidine (MIBG) cardiac imaging has been proposed to detect early cardiac impairment. The aim of this systematic review was to evaluate the performance of MIBG cardiac scan in this scenario.
Methods And Results:
A systematic search was conducted in five international databases comparing MIBG parameters with EF for evaluation of cardiotoxicity. Twelve studies were included and separated in three groups. First, studies evaluating patients with established cardiotoxicity, in which EF was reduced and MIBG parameters were abnormal. Second, studies analyzing patients during or after treatment compared to controls, with MIBG parameters significantly different between groups in most studies, even when EF remained normal. Finally, studies analyzing anthracycline (ATC) dose-related changes, with alteration in MIBG parameters occurring even when EF was preserved.
Conclusion:
Although studies had high methodological variability, cardiac sympathetic innervation imaging seems to be a promising tool for assessing early cardiotoxicity. Further studies are needed to analyze its diagnostic value in this scenario.
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...