Claudius Illg1, Sabrina Krauss1, Jens Rothenberger2
1Department of Hand, Plastic and Reconstructive Surgery, BG Unfallklinik Tuebingen, Eberhard Karls University Tuebingen, Germany.
Journal of Reconstructive Microsurgery
|July 6, 2021
Summary
Dynamic infrared imaging aids anterolateral thigh (ALT) free flap planning. A simplified precooling protocol using a fan and alcohol disinfection improves thermogram clarity and efficiency for perforator mapping.
Area of Science:
- Plastic Surgery
- Microsurgery
- Surgical Anatomy
Background:
- Preoperative perforator mapping is crucial for anterolateral thigh (ALT) free flap harvesting due to variable vascular anatomy.
- Dynamic infrared imaging offers a non-invasive method to visualize angiosomes and assist in preoperative planning.
- Standardized protocols are needed to optimize ALT perforator planning using thermal imaging.
Purpose of the Study:
- To compare different precooling methods for dynamic infrared perforator imaging.
- To develop a standardized and simplified protocol for ALT perforator planning.
- To evaluate the efficacy of thermal imaging in conjunction with Doppler ultrasonography.
Main Methods:
- Fifty thighs were examined using a FLIR ONE thermal camera.
- Four precooling methods were compared: alcoholic disinfection, wet sponge cooling, fan cooling, and cold pack application.
- Thermographic hot spot locations were compared to Doppler ultrasonography findings in a double-blinded manner.
Main Results:
- The overall matching rate between thermographic hot spots and perforators was 34.9%.
- This rate increased to 62.2% when considering only clinically relevant perforators (e.g., larger diameter, specific course).
- Fan cooling followed by alcoholic disinfection yielded the clearest thermograms and fastest results.
Conclusions:
- Dynamic infrared imaging is a reliable adjunct to ultrasound for perforator imaging.
- Simplified precooling methods like fan cooling or alcoholic disinfection enhance thermogram quality.
- Focusing on clinically relevant perforators improves the accuracy of thermal mapping, reducing distraction from non-essential vessels.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
762
Here is a stepwise guide to assessing the body temperature at the temporal artery using a temporal artery thermometer
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
762
Assessing Body Temperature - Axilla
845
Procedural Guide for Assessing Axillary Body Temperature using a Digital Thermometer:
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
845