Related Experiment Video
Updated: Oct 29, 2025

Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
Left ventricular noncompaction in pediatric population: could cardiovascular magnetic resonance derived fractal
Sylvia Krupickova1,2,3, Suzan Hatipoglu2, Giovanni DiSalvo1,3
1Department of Paediatric Cardiology, Imperial College and Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK.
Background:
Cardiovascular magnetic resonance (CMR) derived fractal analysis of the left ventricle (LV) has been shown in adults to be a useful quantitative measure of trabeculation with high reproducibility and accuracy for the diagnosis of LV non-compaction (LVNC). The aim of this study was to investigate the utility and feasibility of fractal analysis in children.
Methods:
Eighty-four subjects underwent CMR: (1) 28 patients with LVNC (as defined by the Petersen criteria with NC/C ratio [Formula: see text] 2.3); (2) 28 patients referred by clinicians for assessment of hyper-trabeculation and found not to qualify as LVNC (NC/C [Formula: see text] 1.8 and < 2.3); (3) 28 controls. The fractal scores for each group were presented as global and maximal fractal dimension as well as for 3 segments of the LV: basal, mid, and apical. Statistical comparison of the fractal scores between the 3 groups was performed.
Results:
Global fractal dimension (FD) was higher in the LVNC group than in the hyper-trabeculated group: 1.345 (SEM 0.053) vs 1.252 (SEM 0.034), p < 0.001 and higher in hyper-trabeculated group than in controls: 1.252 (SEM 0.034) vs 1.158 (SEM 0.038), p < 0.001. The highest maximum FD was in the apical portion of the LV in the LVNC group, (1.467; SEM 0.035) whereas it was in the mid ventricle in the hyper-trabeculated (1.327; SEM 0.025) and healthy groups (1.251; SEM 0.042). Fractal analysis showed lower intra- and interobserver variability than the Petersen and Jacquier methods.
Conclusions:
It is technically feasible to perform fractal analysis in children using CMR and that it is quick, accurate and reproducible. Fractal scoring accurately distinguishes between LVNC, hyper-trabeculation and healthy controls as defined by the Petersen criteria.
Related Concept Videos
Mitral Stenosis II: Clinical features and Diagnostic Tests
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Aortic Regurgitation II: Clinical Features and Diagnostic Tests