Detection Limits of Trinitrotoluene and Ammonium Nitrate in Soil by Raman Spectroscopy
Trevor R Schlack1, Samuel A Beal1, Elizabeth J Corriveau1
1U.S. Army Engineer Research and Development Center, Cold Regions Research and Engineering Lab, 72 Lyme Road, Hanover, New Hampshire 03755, United States.
Abstract:
The detection limit of 2,4,6-trinitrotoluene (TNT) and ammonium nitrate (AN) in mixtures of Ottawa sand (OS) was studied using a Raman microscope applying conventional calibration curves, Pearson correlation coefficients, and two-sample t-tests. By constructing calibration curves, the conventionally defined detection limits were estimated to be 1.9 ± 0.4% by mass in OS and 1.9 ± 0.3% by mass in OS for TNT and AN. Both TNT and AN were detectable in concentrations as low as 1% by mass when Pearson correlation coefficients were used to compare averaged spectra to a library containing spectra from a range of soil types. AN was detectable in concentrations as low as 1% by mass when a test sample of spectra was compared to the same library using two-sample t-tests. TNT was not detectable at a concentration of 1% by mass when using two-sample t-tests.
More Related Videos
07:52A Novel Technique for Raman Analysis of Highly Radioactive Samples Using Any Standard Micro-Raman Spectrometer
Published on: April 12, 2017
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
NMR Spectroscopy of Aromatic Compounds
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
NMR Spectroscopy Of Amines