Related Experiment Video
Updated: Oct 29, 2025

Potentiodynamic Corrosion Testing
Published on: September 4, 2016
Metallosis in Sequelae of Prosthetic Revision for Ceramic Components Fracture: A Case Report with Clinical
Stefano Artiaco1, Federico Fusini1, Kristijan Zoccola1
1Department of Orthopaedics and Traumatology, Orthopaedic and Trauma Center, Azienda Ospedaliero Universitaria Città della Salute e della Scienza, Turin, Italy.
Abstract:
Ceramic on ceramic total hip arthroplasties have been developed and widely used during last decades because of their long-term survival and biomechanical properties. One of the most dangerous complication of these implants is the fracture of the ceramic components. The management of this condition should be carefully planned and the choice of the new implant is crucial. We describe a rare case of severe hip synovitis due to massive metallosis in sequelae of mismanaged prosthetic revision for fracture of the ceramic acetabular liner with an unusual clinical presentation that simulate a periprosthetic infection.