DERIVATION OF LOCAL DIAGNOSTIC REFERENCE LEVELS FOR COMMON ADULT COMPUTED TOMOGRAPHY EXAMINATIONS IN MOROCCAN
M Benmessaoud1, A Housni2, M Elmabrouki2
1Faculty of Sciences Dhar EL Mahraz, Sidi Mohamed Ben Abdellah University, B.P.30000, Fez, Morocco.
Abstract:
The purpose was to derive local diagnostic reference levels (LDRLs) for adults common computed tomography (CT) examinations in Moroccan hospital. The data of patients were collected retrospectively from one facility for 2 months period. The proposed LDRLs were defined as 75th percentile of spreads for CT dose index-volume (CTDIvol) and dose length product (DLP). Findings were compared with diagnostic reference levels (DRLs) of France, Australia and Egypt. A total of 259 cases were enrolled including 53% of male and 47% of female. The corresponding LDRLs in terms of CTDIvol (mGy) were 58, 15, 15 and 14 for head, chest, abdomen-pelvis and chest-abdomen-pelvis CT examinations, respectively. For DLP (mGy.cm) were 1298, 944, 1874 and 2026, respectively. The proposed LDRLs for CTDIvol were almost similar to DRLs of Australia, higher than those of France and lower than Egyptian DRLs. In terms of DLP, LDRLs were higher than compared studies with exception of head CT, which were lower and higher for CTDIvol than Egyptian DRLs. The results highlight higher radiation doses during adult CT scans, indicating the need to spread the same investigation regarding other imaging procedures including different radiological examinations across Moroccan hospitals.
More Related Videos
06:33Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013
12:32Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT