Related Experiment Video
Updated: Oct 29, 2025

Measuring the Motor Aspect of Cancer-Related Fatigue using a Handheld Dynamometer
Published on: February 20, 2020
Evaluating Test-Retest Reliability of Fatigability in Chronic Stroke
Alyssa D Stookey1, Richard F Macko2, Frederick M Ivey3
1Geriatric Research, Education and Clinical Center (GRECC), VA Maryland Health Care System, Baltimore, MD, United States; Division of Gerontology and Geriatric Medicine, Department of Medicine, University of Maryland School of Medicine, Baltimore, MD, United States.
This study shows that measuring fatigability during the 6-minute walk test (6MW) is a reliable way to assess fatigue in stroke survivors. Objective fatigability measures correlate strongly with walking performance and aerobic capacity.
Area of Science:
- Neurology
- Rehabilitation Medicine
- Exercise Physiology
Background:
- Post-stroke fatigue is subjectively reported, leading to variable prevalence rates.
- Objective measures of performance fatigue may provide a more consistent assessment of fatigue in stroke survivors.
Purpose of the Study:
- To determine the test-retest reliability of fatigability measured during the 6-minute walk (6MW) test in individuals with hemiparetic stroke.
- To explore the relationships between stroke-related fatigability and other functional and physiological measures.
Main Methods:
- Twenty-three hemiparetic stroke survivors completed two 6MW tests at least 48 hours apart.
- Fatigability was calculated as the ratio of change in walking speed to distance covered during the 6MW.
- Measurements included oxygen consumption (VO2), peak aerobic capacity (VO2peak), walking speed, Dynamic Gait Index (DGI), and subjective fatigue.
Main Results:
- Fatigability demonstrated high test-retest reliability (ICC = 0.99, p < 0.001) with no significant difference between trials.
- Strong correlations were found between fatigability and 6MW oxygen consumption (VO2) (r = 0.92-0.95, p < 0.001).
- Moderate-to-strong relationships were observed between fatigability and various walking speeds, VO2peak, and DGI (r = -0.47 to -0.82, p < 0.001).
Conclusions:
- The 6MW test provides a reliable and objective method for assessing fatigability in stroke survivors.
- Fatigability is closely linked to functional mobility and aerobic capacity in this population, offering insights into underlying contributors.
More Related Videos
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
04:24Acupoint Application as a Traditional Chinese Medicine Treatment for Fatigue Associated with Chronic Obstructive Pulmonary Disease
Published on: September 5, 2025