Related Experiment Video
Updated: Jul 20, 2026

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
Feasibility of nuclide-identified imaging based on the back-streaming white neutron beam at the China Spallation
Binbin Tian1, Hantao Jing2, Sheng Wang1
1School of Energy and Power Engineering, Xi'an Jiaotong University, No. 28, Xianning West Road, Xi'an 710049, Shaanxi, China.
Abstract:
Back-streaming neutrons through the incoming proton channel at the spallation target station of the China Spallation Neutron Source have been studied as a white neutron source (Back-n). We report a physical study on white neutron imaging based on the Back-n beamline. The wide neutron energy spectrum spanning from 1 eV to 100 MeV was very suitable for nuclide-identified imaging as well as measurements of nuclear data and other applications. We calculated the back-streaming white neutron energy spectrum using the Monte Carlo N-Particle code. A comparison of the results of calculation with those of the FLUktuierende KAskade code and experimental measurements were carried out. The energy resolution of the Back-n beam was close to 5% depending on the neutron energy and the modes of operation, and its spatial resolution could attain the order of tens of micrometers.