Applying X-ray Imaging Crystal Spectroscopy for Use as a High Temperature Plasma Diagnostic
Published on: August 25, 2016
Comprehensive imaging of C-2W plasmas: Instruments and applications
E M Granstedt1, D Gupta1, J Sweeney1
1TAE Technologies, Inc., 19631 Pauling, Foothill Ranch, California 92610, USA.
Abstract:
The C-2W device ("Norman") [Gota et al., Nucl. Fusion 59, 112009 (2019)] has produced and sustained beam-driven field-reversed configuration (FRC) plasmas embedded in a magnetic mirror geometry using neutral beams and end-bias electrodes located in expander divertors. Several discrete vessels comprise this device, and many imaging instruments are required in order to view the plasma throughout. To meet this need, a suite of spatially and radiometrically calibrated, high-speed camera systems have been deployed. Besides global visualization of the plasma evolution and macro-stability, this imaging suite has been used in a variety of applications. One example application is a tomographic reconstruction of passive impurity emission. Calculation of the magnetic field in the equilibrium vessel is complicated by eddy currents in conducting structures and internal currents in the high-β FRC plasma. In addition, thus far non-perturbative measurements of internal field have not been available. The tomographic reconstruction of O4+ impurity emission enables an independent visualization of the plasma geometry, serving as a check on magnetic modeling and indirect evidence for field reversal within the FRC. A second application uses the cameras to view the Balmer-α emission throughout the plasma in order to estimate the ionization rate in each region. These rates can then be incorporated into particle balance calculations and a circuit model for currents from the end-bias electrodes. Finally, arcing on the electrode surfaces is identified through automated image processing of carefully selected spectral line emission.
Related Concept Videos
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview