Research on a modularized long pulse generator based on anti-resonance network and transmission line transformer

Xinbing Cheng1, Rong Chen1, Zilong Pan1

  • 1College of Advanced Interdisciplinary Studies, National University of Defense Technology, Changsha 410073, China.

Related Concept Videos

Transmission Line Design Considerations01:23

Transmission Line Design Considerations

Aluminum has become the material of choice for overhead transmission lines, surpassing copper due to its abundance and cost-effectiveness. The most prevalent type is the aluminum conductor, steel-reinforced (ACSR), which combines aluminum strands around a steel core. Other variants include all-aluminum conductors (AAC), all-aluminum alloy conductors (AAAC), aluminum conductor alloy-reinforced (ACAR), and aluminum-clad steel conductors. Advanced designs, such as aluminum conductors with steel...
247
Parallel RLC Circuits01:14

Parallel RLC Circuits

Street lamps equipped with RLC surge protectors are an excellent example of applying circuit analysis in practical scenarios. These surge protectors safeguard the lamp's components against sudden voltage spikes.
A simplified parallel RLC circuit model with a DC input source generating a step response is employed in this context. When the switch is turned on, Kirchhoff's current law is applied, leading to a second-order differential equation.
1.2K
Equivalent Circuits for Practical Transformers01:28

Equivalent Circuits for Practical Transformers

The practical equivalent circuits of single-phase two-winding transformers exhibit significant deviations from their idealized versions due to the inherent properties of winding resistance and finite core permeability. These properties result in real and reactive power losses, affecting the transformer's performance. Understanding these deviations is crucial for designing more efficient transformers.
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
892
Characteristics of Series Resonant Circuit01:24

Characteristics of Series Resonant Circuit

Series resonance occurs in a circuit containing inductive (L), capacitive (C), and resistive (R) elements connected sequentially. At the resonance frequency, the inductive and capacitive reactances are equal in magnitude but opposite in sign, effectively canceling each other. This causes the circuit's impedance is minimal, primarily determined by the resistance R. The resonant frequency of an RLC circuit is defined as:
373
Reducing Line Loss01:18

Reducing Line Loss

In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
226
Parallel Resonance01:23

Parallel Resonance

The parallel RLC circuit is an arrangement where the resistor (R), inductor (L), and capacitor (C) are all connected to the same nodes and, as a result, share the same voltage across them. The parallel RLC circuit is analyzed in terms of admittance (Y), which reflects the ease with which current can flow. The admittance is given by:
316