Computed tomography evaluation of proposed implant corridors in canine thoracic vertebrae
Elizabeth M Schmitt1, Peter Early2, Robert Bergman3
1Department of Veterinary Clinical Sciences, Iowa State University College of Veterinary Medicine, Ames, Iowa, USA.
Objective:
Identify acceptable implant corridors in the normal canine thoracic vertebrae (T) from T1 to T9.
Study Design:
Retrospective study.
Sample Population:
Computed tomographic (CT) studies of normal canine thoracic spines (n = 39).
Methods:
CT imaging studies of normal T1-T9 canine spines were evaluated by five independent observers. Each identified a proposed corridor, measured the width, length, and angle off mid-sagittal that the corridor occupied.
Results:
CT studies were from 39 dogs weighing 3.19-60 kg (mean 10.72, SD 9.9 kg). Vertebral corridors ranged in average width from 3.8 to 5.2 mm, the widest being located at T1. They ranged in average length from 13.3 to 17.5 mm, shortest being T1 and longest being T6. The angle of corridors varied the most between individual vertebrae at T1-T3. The average corridor angles were: T1 = 38°, T2 = 32°, T3 = 27°, T4 = 26°. T5-T9 angle ranged from 23° to 24°.
Conclusion:
The average dimensions of corridors measured in dogs weighing 3.1-60 kg were consistent with those of commercially available cortical screws and pins.
Clinical Significance:
Corridor trajectories identified in this population can be achieved from a dorsal approach between T5 and T9. A dorsal approach for implant placement would be challenging for T1-T4 due to the variability found in these vertebrae as well as regional anatomical constraints.
More Related Videos
06:18Pedicle Screw Placement Using an Augmented Reality Head-Mounted Display in a Porcine Model
Published on: May 24, 2024
07:12Semiautomated Longitudinal Microcomputed Tomography-based Quantitative Structural Analysis of a Nude Rat Osteoporosis-related Vertebral Fracture Model
Published on: September 28, 2017
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...