Related Experiment Video
Updated: Oct 29, 2025

Author Spotlight: Demonstrating Systematic Endobronchial Ultrasound to New Endoscopists
Published on: August 11, 2023
Factors related to oxygen desaturation during flexible bronchoscopy and endobronchial ultrasound
İlim Irmak1, Fatih Tekin1, Lütfi Çöplü1
1Hacettepe University Faculty of Medicine, Department of Chest Diseases, Ankara, Turkey.
Introduction:
Oxygen desaturation is a significant event during bronchoscopy. In this study, it was aimed to identify factors related to oxygen desaturation during flexible bronchoscopy (FB) and Endobronchial ultrasound (EBUS).
Materials And Methods:
From 16 April 2019 to 14 February 2020, 196 consecutive patients (146 FB and 50 EBUS) undergoing bronchoscopy were evaluated retrospectively. The patients' oxygen saturations were monitored on admission and during the procedure by finger pulse oximetry. Desaturation was defined as saturation below 90%. Demographic characteristics, comorbidities, types of interventions, vitals before and during the procedure, amount of saturation decline, and sedative agents used were recorded. The data obtained were compared between the desaturated and non-desaturated groups in both FB and EBUS. We evaluated the risk factors for desaturation during bronchoscopic procedures.
Result:
The mean age of those who underwent FB was higher (62 [52-68] years vs. 55 [44-65] years, p= 0.05), and males were more frequent (54%, vs 19.2%, p<0.001) in the desaturated group. In FB, short lavage was more frequent in the non-desaturated group (28.8% vs. 9.5%, p<0.001). In EBUS, hypertension, diabetes mellitus and thyroid diseases were higher, and duration of procedure was longer (p= 0.02, p= 0.04, p= 0.01 and p<0.001 and p= 0.01, respectively), and SpO2 decline during procedures was higher (11% vs. 1% in FB, 18% vs. 3% in EBUS, p<0.001, each) in the desaturated group.
Conclusions:
This study suggested that baseline SpO2 and SpO2 decline during procedures as well as sex, hypertension, and concomitant endocrine - metabolic diseases, duration of procedure were factors associated with desaturation in patients who had undergone FB and EBUS.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...

