Related Experiment Video
Updated: Oct 29, 2025

Detection and Removal of Tooth-Colored Composite Resin Using the Fluorescence-Aided Identification Technique
Published on: July 27, 2022
Spectrophotometric Analysis of Different Flowable Restorative Materials
Abeer E ElEmbaby1, Mouneir Slais2, Ali Alawami2
1Department of Restorative Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia, Phone: +966 38574928,
Aim:
To compare the color change of three flowable composites after exposure to staining solutions.
Materials And Methods:
A total of 240 oval samples were constructed of conventional flowable resin composite, self-adhesive flowable resin composite, and nanohybrid flowable ormocer (n = 80). Each set was further subcategorized into three subsets as regards staining solution. The baseline color parameters were recorded using spectrophotometer after the immersion of the specimens in artificial saliva for 24 hours. Then, the measurements were taken again after exposure to staining solutions where the color change was measured as ΔE* = V (ΔL*2 + Δa*2 + Δb*2).
Results:
Conventional flowable resin composite had the best color stability in all staining solutions. The coffee was concluded to be the most staining solution. Compared to beverages, mouthwashes had a greater discoloration effect on nanohybrid flowable ormocer than on selfadhesive flowable composite.
Conclusion:
Conventional flowable composite had the highest color stability among the tested materials, followed by flowable nanohybrid ormocer, and the least was self-adhering flowable composite. Coffee had the greatest discoloration effect, followed by a sports drink and then the energy drink. However, mouthwashes did not have a significant discoloration effect.
Clinical Significance:
Selection of flowable composite materials that are resistant to staining by coffee, beverages, or mouthwashes is an important factor that may influence the sustainability of the esthetic quality of the restoration.
More Related Videos
Related Concept Videos
Flow Table Test
Concrete is placed within a truncated cone mold that is 8 inches high with an 8-inch base diameter and a 5-inch top diameter. The...
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
Photoluminescence: Applications