Related Experiment Video
Updated: Oct 29, 2025

The Modified Single-working Portal Technique Using Lasso-loop Stitch with Needle for Arthroscopic Subscapularis Repair
Published on: August 8, 2025
Suprameniscal Portal for Repairing Meniscal Root Tears
Ahmed Fouad Seifeldin1, Ahmed Khedr1
1Faculty of Medicine, Cairo University, Cairo, Egypt.
Abstract:
Several techniques and portals have been described for meniscal root repairs. Some authors describe using anterior portals for suture passing and manipulation of meniscal tissue, with some risk of iatrogenic chondral injuries reported. Other authors describe using posterior portals to avoid this risk. In this technique, we used a suprameniscal portal, which allowed a good trajectory for passing sutures in the meniscal tissue with minimal risk of iatrogenic chondral damage without the need to use posterior portals. The meniscal bed is first prepared. The suprameniscal portal is created in 15° of knee flexion and used to pass 2 sutures through the meniscus by a Lasso. The sutures are tied in a cinch configuration, shuttled through the tibial tunnel, and tied over a Dog Bone button.