Related Experiment Video
Updated: Oct 28, 2025

Continuous Manual Exchange Transfusion for Patients with Sickle Cell Disease: An Efficient Method to Avoid Iron Overload
Published on: March 14, 2017
Emergency departments are higher-risk locations for wrong blood in tube errors
Nancy M Dunbar1, Meghan Delaney2, Michael F Murphy3
1Department of Pathology and Laboratory Medicine, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire, USA.
Background:
Wrong blood in tube (WBIT) errors can lead to ABO mistransfusions. It is unknown if WBIT errors are more likely in specific healthcare locations or if specific collection practices influence the commission of WBIT errors.
Study Design And Methods:
Data on pretransfusion samples from calendar year 2019 were collected retrospectively by 39 transfusion services in nine countries. We compared the proportion of WBIT errors made in emergency departments (EDs), inpatient wards, and outpatient clinics.
Results:
In total, 143 WBIT errors were detected among 1,394,862 samples for an unadjusted aggregate WBIT proportion of 1.03/10,000 samples. Using a pooled random effects model, the WBIT proportion was estimated to be significantly higher in EDs (1.23/10,000 samples, 95% CI 0.62-2.43) than inpatient wards (0.71/10,000, 95% CI 0.44-1.14; p < .001) or outpatient clinics (0.24/10,000, 95% CI 0.08-0.65; p < .001) and significantly higher in inpatient wards than outpatient clinics (p = .043). The use of electronic positive patient identification (ePPID) systems was associated with a significantly lower WBIT proportion in the ED (odds ratio, OR: 0.32, 95% CI: 0.11-0.96, p = .041), but not in inpatient wards (OR: 0.45, 95% CI: 0.20-1.01, p = .054) or outpatient clinics (OR: 1.95, 95% CI: 0.39-9.74, p = .415).
Discussion:
Normalized for the number of samples drawn per location, the WBIT proportion in EDs was 1.7 times higher than inpatient wards and 5.1 times higher than outpatient clinics. EDs represent higher-risk clinical locations for WBIT errors, and electronic positive patient identification (ePPID) may provide a greater impact on safety in EDs relative to other clinical areas.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Blood Transfusion
Blood Transfusion Overview
A blood transfusion is a medical procedure used to replace blood lost due to injury, surgery, or to treat conditions such as anemia or cancer. During a transfusion, donor blood is...
Blood Transfusion and Agglutination
History
The history of blood transfusion dates back to the 17th century, when early attempts were made in animals. In 1818 James Blundell, a British doctor, performed the first successful human blood transfusion. Later in 1900, Karl...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to...
Cardiac Catheterization II: Right Heart Catheterization

